3
care.elzab.p
l
EN
carefully place the device on its side, on a flat surface
(manually) remove 3 bolts fixing the filter cassette to the base
slide out the filter cassette
(sliding in the inclined position is necessary due to protruding elements)
slide out the filter
replace it with a new filter
make sure that the power cord is correctly connected and slide
in the filter cassette
(check 2 guiding pins)
(manually) insert the 3 fixing bolts
carefully put the device in the proper position
6
7
8
1
2
3
6
4
5
Fig. 2
Replacement of the upper filter (
Fig.
3)
replacement once a year
carefully place the device on its side, on a flat surface
remove the lower filter cassette
(points 2 - 3 in the lower filter replacement, Fig. 2)
remove the power cord
remove 4 screws of the upper cover
(use the Torx driver provided with the device)
carefully slide out the upper part of the internal unit
slide out the filter
5
1
2
3
4
6
3
5
4
2
Replacement of the lower filter (
Fig.
2)
replacement every 4 - 6 weeks (depending on environmental pollution)
1