TROUBLESHOOTING
N.B.
- If the problem persists, contact your Retailer or the nearest Service Centre
PROBLEM
PROBABLE CAUSE
SOLUTION
On giving a command with the remote control or
with the key-switch, the gate doesn’t open or the
motor doesn’t start
230 volt mains voltage absent
Check master switch
Emergency STOP present
Check for any STOP selectors or commands.
If not used, check jumper on STOP contact input
on the control board.
Fuse blown
Replace with one of same value.
Power cable of motor or motors not connected or
faulty.
Connect the cable to appropriate terminal or re-
place.
The photocell is not functioning or the beam is in-
terrupted
Check the connection, remove any obstacle across
the beam
On giving a command with the remote control, the
gate doesn’t open but works with the key com-
mand
The remote control has not been memorised or the
battery is flat
Carry out the remote control learning procedure on
the radio receiver or replace the battery with a new
one.
The gate starts, but stops immediately
The force of the motor or motors is insufficient
Modify the value with the FORCE trimmer on the
control unit
One wing opens and the other closes
The connection is not correct
Invert the connection of the cable of the motor
which rotates in the wrong sense.
10/28
EA60 - EA80
GB
MAINTENANCE
. To guarantee the product performance professionaly qualified personnel must carry out the maintenance in the time pre-established by the in-
staller, the producer and the legislation in force.
. Services concerning the installation, the maintenance, repair work and cleaning must be proved by proper documentation. Such documentation
must be kept by the user, at complete disposal of the qualified personnel in charge.
. Before carrying out the maintenance or cleaning disconnect the appliance from the mains unplugging the power cord or switching off the instal-
lation. In case the installation must be powered during the check up of the operation, it is advised to control and disable any control device (radio
controls, keypads etc.), with the exception of the device used by the maintenance personnel.
Routine maintenance
Each of the following operations must be carried out when required, in any case, they are compulsory every year.
Gate:
Lubricate the hinges on which the gate swings mechanically.
Automatic gate system:
Check the security devices operation (photocells, switch trim etc.)
Extraordinary maintenance
Extraordinary maintenance cannot be forseen. Anyhow, if particular repair works should be carried out on mechanical parts it is advised to remove
the actuator to allow repair works by authorized personnel.
DISMANTLING - DISPOSAL
When it is decided to discontinue use of either the actuator or the entire automatic system, it is recommended that is removed and, where possi-
ble, recycled in line with the relevant standards.
Installation of mechanical limit stops.
At the open and closed positions of the sliding gate, it is recommended that mechanical limit stops are fitted which are able to stop the movement
of the gate during both opening and closing. Always follow the recommendations of the various relevant standards.