4 OSD Menu
WORKING MODE:
Working mode has auto, black/white, color selectable. Default is auto.
TESTING TIME:
On IR auto working mode and the programmed time, the IR will execute the programmed action, eg. Switch from day to night or from
night to day. The detection time is from 2s to 15s selectable.
OUTPUT POWER:
Output power has 40%,60%,80%,100% for selection!
ILLUMINATION ON:
Illumination on is 1 to15 grade selectable and default is 3. On the auto IR working mode, if the illumination on level is less than the
ambient light, the picture will change to color, the IR illumination will turn off automatically. If the illumination on level is more than the ambient light, the
picture will change to black , the IR illumination will turn on automatically.
AMBIENT LIGHT:
Ambient light is a system data. User can not change it manually. It changes according to the environment all the time. The data will
refresh every time when user enter the OSD. It is from 0 to 50 grade.
IR SWITCH ZOOM:
When zoom value reaches to the demanded setting, the IR LEDs with auto switch from near illumination to far illumination, zoom
value option from 01-23.
4.3.3 Guard Tours
EN
<GUARD TOURS>
GUARD TOUR 01
<SETTING>
INIT
RUNNING
DELETE
EXIT
<GUARD TOUR 01>
ID POINT TIME(S) SPEED
1 01 06 64
2 02 06 64
3 03 06 64
4 04 06 64
5 05 06 64
6 06 06 64
7 07 06 64
8 08 06 64
GUARD TOUR:
Total 8 guard tours selectable: 01, 02, 08.
SETTING:
Each guard tour includes max 16 presets. The number of the preset is from 0-16, but 0 is not valid.
Dwell time is 1 to 60s selectable. Speed is 1 to 64 grade selectable.
INIT:
After init., preset point, dwell time, speed will resume to default setting.
RUNNING:
Running the present guard tour.
DELETE:
Delete the guard tour set. After deleting, the present preset points in the guard tours all display as 0. While the exact preset point information
doesn’t be deleted. So it is convenient for user to select the preset point needing to be guarded tour.
4.3.4 A-B Scan
<A-B SCAN>
PRESET A
PRESET B
SCAN SPEED 20
DWELL TIME 06S
RUNNING
DELETE
EXIT
A-B SCAN
RUNNING….
PRESET 1:SAVE
PRESET 2:BACK
Fig. 4.3.4.1 Fig. 4.3.4.2
SCAN SPEED:
A-B scan speed is 1 to 64 grade selectable.
DWELL TIME:
Dwell time between A to B is 2s to 60s selectable.
RUNNING:
Running the A-B scan. Check Fig. 4.3.4.2.
DELETE:
After deleted, the preset points of A and B display as 0. While the exact preset point information doesn’t be deleted. So it is convenient for
user to select the preset point needing to be scanned. Speed and dwell time will reset as default setting.
4.3.5 Pan Scan
<PAN SCAN>
PAN SCAN SPEED 20
INIT
RUNNING
EXIT
PAN SCAN
RUNNING….
PAN SCAN SPEED:
Pan scan speed is 1 to 64 grade selectable.
INIT:
Reset the scan speed and tilt degree as default setting.
RUNNING:
Running the scan speed and tilt degree set.
4.3.6 Pattern
<PATTERN>
PATTERN NO OFF
<SETTING>
RUNNING
DELETE
EXIT
<PATTERN>
PRESET 1 SAVE AND BACK
PRESET 2 BACK LAST MENU