Elvox 46535.020B Installation And Operation Manual Download Page 33

   31

VIMAR group

4 OSD Menu

4.5 Display

<DISPLAY>

P AND T                ON
ZOOM                   ON
ACTION                 ON
DOME ID               ON
COMM                  ON
TIME                     OFF

P AND T: 

On screen, it displays the pan and tilt degree, user can enable or disable it. 

ZOOM: 

Displays the zoom level.

ACTION: 

On the screen, it displays the current action, such as A-B scan, Call preset, Save preset, Call park action, Pan scan etc. User can enable or 

disable it

DOME ID: 

At the top left corner of screen, it displays the dome ID. User can enable or disable it. 

COMM: 

At the top left corner of screen, it displays the dome communication information. User can enable or disable it. 

TIME: 

Displays the current time on screen.

4.6 Language

<LANGUAGE>

LANGUAGE           ENGLISH
EXIT

LANGUAGE: 

Language can be set as English, Espanol, Francais, Portugues, Polski, Deutsch, Italiano and so on. Default language is English.

4.7 Timing task

<TIMING TASK>

<TIME SETTING>
<TIMING TASK>
EXIT

 <TIMING TASK>

  START    END             FUNCTION
- 00  00 -  00  00          OFF
- 00  00 -  00  00          OFF
- 00  00 -  00  00          OFF
- 00  00 -  00  00          OFF
- 00  00 -  00  00          OFF
- 00  00 -  00  00          OFF
EXIT

<TIMING SETTING>

TIME-YEAR                 2016
TIME-MONTH             01
TIME-DATE                 06
TIME-HOUR               15
TIME-MIN                  34
TIME-SEC                  56
SAVE
EXIT

4.8 Alarm

<ALARM>

ALARM NO                          01
ALARM MODE                     OFF
PRIORITY LEVEL                 OFF
ALARM IN                           LOW
ALARM ACTIO PRESET       1
ALARM OUT                        NO
RELEASE TIME                    OFF
PATROL TIME                      06
EXIT

ALARM NO: 

Alarm has OFF and ON selectable.

ALARM MODE: 

Alarm linkage has OFF and ON selectable.

PRIORITY LEVEL: 

To run alarm 1, presets 1-04 are available.

ALARM IN: 

Alarm in has low input and high input selectable.

ALARM ACTIO PRESET: 

When prior is none, alarm action preset point 1-8 selectable, when prior is 1-4 level, alarm action has pattern, guard tour, 360 

scan, preset scan and preset point 1-8 selectable.

ALARM OUT: 

Alarm out has NC (normal close) and NO (normal open) selectable.

RELEASE TIME: 

Alarming release time, 2-60s selectable, the default is OFF.

PATROL TIME: 

Patrol time is 2~60s selectable.

BLUE

AL1

PURPLE

AL2

GREY

AL3

BROWN

AL4

WHITE/BLACK

GND

GREEN

NC

WHITE

COM

PINK

NO

Reference cables PTZ, I/O 

Summary of Contents for 46535.020B

Page 1: ...Manuale per il collegamento e l uso Installation and operation manual 46535 020B Telecamera Speed Dome 20X AHD 2Mpx IR 150m 20X AHD 2Mpx IR 150m Speed Dome Camera...

Page 2: ...IMPORTANTI MISURE DI SICUREZZA 1 Leggere le istruzioni prima di installare o mettere in funzione il dispositivo dome 2 Conservare queste istruzioni per futura consultazione 3 Prestare attenzione alle...

Page 3: ...4 2 Informazioni di sistema 11 4 3 Dome 11 4 3 1 Comunicazioni 11 4 3 2 IR 11 4 3 3 Giri di sorveglianza 12 4 3 4 Scansione A B 12 4 3 5 Scansione Pan 12 4 3 6 Pattern 13 4 3 7 Azione parcheggio 13 4...

Page 4: ...izzata nel menu a video disponibile inglese ecc L utente pu impostare la funzione o il parametro o verificare le informazioni correlate tramite l OSD Privacy Mask Maschera privacy Ai fini del monitora...

Page 5: ...so orario a una velocit impostata e con angolo di inclinazione costante Preset Dopo avere preregolato una certa posizione PTZ la telecamera dome si sposta automaticamente alla posizione impostata quan...

Page 6: ...ia in interno che in esterno La parete deve sopportare almeno 4 volte il peso della telecamera dome Installazione della staffa da parete a Come mostrato in Fig 2 utilizzare come riferimento i fori pre...

Page 7: ...accessori per il montaggio ad angolo e la staffa da parete a Come mostrato in Fig 5 utilizzare come riferimento i fori presenti sull accessorio per il montaggio ad angolo segnare i punti di foratura...

Page 8: ...o da 15 24 cm adatte a pali di diametro 130 152 mm Il palo deve sopportare almeno 4 volte il peso della telecamera dome Installazione degli accessori per il montaggio ad angolo e la staffa da parete a...

Page 9: ...ta installabile su soffitti solidi di spessore tale da consentire l utilizzo dei tasselli a espansione sia in interno che in esterno Il soffitto deve sopportare almeno 4 volte il peso della telecamera...

Page 10: ...icone Fig 13 Nota se la telecamera utilizzata all esterno per garantire l impermeabilit applicare silicone tra la superficie di contatto della base del supporto e il soffitto nonch intorno a tutti i f...

Page 11: ...ichiamo preset premere il tasto numero preset Nota alcuni punti preset sono utilizzati da funzioni speciali 3 3 Comandi a scelta rapida I preset seguenti sono riservati a funzioni speciali premere sho...

Page 12: ...10 4 Menu OSD IT 4 1 Indice dei menu...

Page 13: ...Comunicazione COMM DEVICE ID 125295 CHECK ID 125288 TARGET ID 000 SOFT PROTOCOL AUTO BAUD RATE 2400 COMM RESET SAVE EXIT COMM RESET RESET TO DIAL THE CODE OK Fig 4 3 1 1 Fig 4 3 1 2 DEVICE ID ID dispo...

Page 14: ...di sorveglianza pu includere fino a un massimo di 16 preset Il valore di preset 0 16 0 non valido Per il tempo di permanenza i valori selezionabili sono compresi tra 1 e 60 s Per la velocit le graduaz...

Page 15: ...imposta i parametri specifici della maschera corrente Richiama il Preset 1 per salvare l impostazione Tasti di direzione Per modificare le coordinate della telecamera Tasti zoom Per modificare la dim...

Page 16: ...0 00 00 OFF 00 00 00 00 OFF 00 00 00 00 OFF 00 00 00 00 OFF 00 00 00 00 OFF 00 00 00 00 OFF EXIT TIME SETTING TIME YEAR 2016 TIME MONTH 01 TIME DATE 06 TIME HOUR 15 TIME MIN 34 TIME SEC 56 SAVE EXIT 4...

Page 17: ...OK SYS DATA CONFIRM FACTORY DEFAULT OK CAM DATA CONFIRM FACTORY DEFAULT OK CONFIRM Conferma elimina le informazioni predefinite salvate dalla telecamera dome IT 5 Controllo automatico della temperatur...

Page 18: ...ratamente l impedenza della messa a terra deve essere inferiore a 4 e l area della sezione del cavo di messa a terra non deve essere inferiore a 25 mm2 Appendice 2 Pulizia del coperchio trasparente Pe...

Page 19: ...eed the maximum specified temperature humidity or power supply specifi cations IMPORTANT SAFEGUARDS 1 Read these instructions before attempting installation or operation of dome device 2 Keep these in...

Page 20: ...Menu 27 4 1 Menu Index 28 4 2 System Information 28 4 3 Dome 28 4 3 1 Communication 28 4 3 2 IR Display 28 4 3 3 Guard Tours 29 4 3 4 A B Scan 29 4 3 5 Pan Scan 29 4 3 6 Pattern 29 4 3 7 Park Action 3...

Page 21: ...heck the related information through the OSD Privacy Mask In the monitoring scope areas that users can t or aren t willing to make show in the screen of the monitor can be set as privacy protected are...

Page 22: ...After the dome camera keeps arbitrary PTZ location it will automatically move to the defined position when preset is called Guard Tour Scan Dome patrol scans according to certain edited preset order...

Page 23: ...on bolt in indoor and outdoor environ ment The wall can bear at least 4 times the weight of the dome Install wall hanging bracket a As shown in fig 2 with the installation holes in the underside of th...

Page 24: ...ght of the dome Install corner mounted attachment and wall hanging bracket a As shown in Fig5 with the installation holes in the corner mounted attachment as pattern draw punched locations on the wall...

Page 25: ...stainless hose clamps fit 130 152mm pillar The pole structure can bear at least 4 times the weight of the dome Install corner mounted attachment and wall hanging bracket a As shown in Fig 9 use the st...

Page 26: ...dome with thick pole can be used in the hard ceiling structure whose thickness should be enough to install expansion bolt in indoor and outdoor environment The ceiling can bear at least 4 times the w...

Page 27: ...ceiling Silica gel Fig 13 Note If the dome is used in the outdoor conditions use the silica gel on the faying surface of the base of hang ceiling and the ceiling board and around the out holes to be s...

Page 28: ...preset Calling preset press buttons number preset Remark Some preset points are used tentatively for special functions 3 3 Shortcut commends The follow presets are predefined as special function pleas...

Page 29: ...27 VIMAR group 4 OSD Menu EN 4 1 Menu index...

Page 30: ...D EXIT 4 3 1 Communication COMM DEVICE ID 125295 CHECK ID 125288 TARGET ID 000 SOFT PROTOCOL AUTO BAUD RATE 2400 COMM RESET SAVE EXIT COMM RESET RESET TO DIAL THE CODE OK Fig 4 3 1 1 Fig 4 3 1 2 DEVIC...

Page 31: ...ARD TOUR Total 8 guard tours selectable 01 02 08 SETTING Each guard tour includes max 16 presets The number of the preset is from 0 16 but 0 is not valid Dwell time is 1 to 60s selectable Speed is 1 t...

Page 32: ...on the number of the module supported MASK Mask has on and off selectable SETTING Set the specific parameter of present mask NO And call preset 1 to save the settings Direction operation Modify the co...

Page 33: ...K START END FUNCTION 00 00 00 00 OFF 00 00 00 00 OFF 00 00 00 00 OFF 00 00 00 00 OFF 00 00 00 00 OFF 00 00 00 00 OFF EXIT TIMING SETTING TIME YEAR 2016 TIME MONTH 01 TIME DATE 06 TIME HOUR 15 TIME MIN...

Page 34: ...TA DOME RESTART OK SYS DATA CONFIRM FACTORY DEFAULT OK CAM DATA CONFIRM FACTORY DEFAULT OK CONFIRM Delete the presets information saved by the dome 5 Auto Temperature Control This product has built in...

Page 35: ...When system is independently grounded grounding impedance should be less than 4 and cross sectional area of grounding conductor must be not less than 25mm2 Appendix 2 Clean Transparent Cover In order...

Page 36: ...Viale Vicenza 14 36063 Marostica VI Italy www vimar com 49401018A0 00 16 05...

Reviews: