31
VIMAR group
4 OSD Menu
4.5 Display
<DISPLAY>
P AND T ON
ZOOM ON
ACTION ON
DOME ID ON
COMM ON
TIME OFF
P AND T:
On screen, it displays the pan and tilt degree, user can enable or disable it.
ZOOM:
Displays the zoom level.
ACTION:
On the screen, it displays the current action, such as A-B scan, Call preset, Save preset, Call park action, Pan scan etc. User can enable or
disable it
DOME ID:
At the top left corner of screen, it displays the dome ID. User can enable or disable it.
COMM:
At the top left corner of screen, it displays the dome communication information. User can enable or disable it.
TIME:
Displays the current time on screen.
4.6 Language
<LANGUAGE>
LANGUAGE ENGLISH
EXIT
LANGUAGE:
Language can be set as English, Espanol, Francais, Portugues, Polski, Deutsch, Italiano and so on. Default language is English.
4.7 Timing task
<TIMING TASK>
<TIME SETTING>
<TIMING TASK>
EXIT
<TIMING TASK>
START END FUNCTION
- 00 00 - 00 00 OFF
- 00 00 - 00 00 OFF
- 00 00 - 00 00 OFF
- 00 00 - 00 00 OFF
- 00 00 - 00 00 OFF
- 00 00 - 00 00 OFF
EXIT
<TIMING SETTING>
TIME-YEAR 2016
TIME-MONTH 01
TIME-DATE 06
TIME-HOUR 15
TIME-MIN 34
TIME-SEC 56
SAVE
EXIT
4.8 Alarm
<ALARM>
ALARM NO 01
ALARM MODE OFF
PRIORITY LEVEL OFF
ALARM IN LOW
ALARM ACTIO PRESET 1
ALARM OUT NO
RELEASE TIME OFF
PATROL TIME 06
EXIT
ALARM NO:
Alarm has OFF and ON selectable.
ALARM MODE:
Alarm linkage has OFF and ON selectable.
PRIORITY LEVEL:
To run alarm 1, presets 1-04 are available.
ALARM IN:
Alarm in has low input and high input selectable.
ALARM ACTIO PRESET:
When prior is none, alarm action preset point 1-8 selectable, when prior is 1-4 level, alarm action has pattern, guard tour, 360
scan, preset scan and preset point 1-8 selectable.
ALARM OUT:
Alarm out has NC (normal close) and NO (normal open) selectable.
RELEASE TIME:
Alarming release time, 2-60s selectable, the default is OFF.
PATROL TIME:
Patrol time is 2~60s selectable.
BLUE
AL1
PURPLE
AL2
GREY
AL3
BROWN
AL4
WHITE/BLACK
GND
GREEN
NC
WHITE
COM
PINK
NO
Reference cables PTZ, I/O