20
Alarm Output:
a) Supports 1 CH alarm output including OPEN and COM connections.
b) Options: OFF, IN1. If the OFF is selected, no alarm can be output. If IN1 are selected, the alarm can be output only when the
corresponding alarm input triggers the alarm.
c) One passive switch for user to connect alarm devices.
- RS485 Connection
You can connect keyboard to control the speed dome through the RS485 interface.
2.3 Install CVM ELVOX
Find CVM ELVOX software from CD and then double click “Setup.exe” file to pop up installation wizard. Install the software
according to the prompts in the wizard. After you complete the installation, you will see the CVM ELVOX and IP-Tool icon on the
desktop. Please see the user manual of this software for more details.
If you need to install IP-Tool separately, please double click IP-Tool installation package and install it according its wizard promp
-
ts. After you finish installing, double click IP-Tool icon to start IP-Tool.
Chapter 3 IE Remote Access
You may connect IP-Cam via LAN or WAN. Here only take IE browser (6.0) for example. The details are as follows:
3.1 LAN
In LAN, there are two ways to access IP-Cam: 1. access through IP-Tool; 2. directly access through IE browser.
3.1.1 Access through IP-Tool
1 - Make sure the PC and IP-Cam are connected to the LAN and the IP-Tool is installed in the PC from the CD.
2 - Double click the IP-Tool icon on the desktop to run this software as shown below:
3 - Modify the IP address. The default IP address of this camera is 192.168.226.201. Click the information of the camera listed
in the above table to show the network information on the right hand. Modify the IP address and gateway of the camera and
make sure its network address is in the same local network segment as the computer’s. Please modify the IP address of
your device according to the practical situation.
EN
- Alarm Connection
Alarm Input:
a) There are seven independent alarm input ports (ALARM-IN1~7) and one grounding port (ALM-GND).
b) There are three alarm input status: “OFF/NC/NO”. If “OFF” is selected, the system will not check the status of the ALM-IN and
ALM-GND. If “NO” is selected, connect DC 5V~DC12V voltage between the alarm input port ALM-IN and the grounding port
(ALM-GND) to trigger the alarm (see Fig. 1). If “NC” is selected, disconnect the voltage between alarm input ports (ALM-IN)
and grounding port (ALM-GND) to trigger the alarm.