70
selves.
After synchronisation the normal transmission program is
continued and the valve operating mechanisms generate
an acoustic signal the moment they receive the first cor
rect signal.
• Press the “PROG” key until “Sond” is displayed.
• Use the selection wheel to select the special function
“SynC”.
• To confirm your selection, briefly press the “PROG” key.
• The safety code is displayed and the heating control
starts to count down from “120” in steps of 1 second. Af
ter these 120 seconds the heating control returns to the
normal operating mode.
g) Test mode (“tESt”)
Use this function to check whether all valve operating
mechanisms receive the radio signal correctly. The tested
valve operating mechanisms acknowledge correct recep
tion with an acoustic signal. Use the selection wheel to se
lect the valve operating mechanisms to be tested.
If the large display shows a “0” (zero), all valve operating
mechanisms are tested, otherwise, only the valve operat
ing mechanism assigned to the displayed number is tested.
The timer in the left corner of the display counts down to the
point in time the next test cycle is to be started.
• Press the “PROG” key until “Sond” is displayed.
• Use the selection wheel to select the special function
“tEST”.
• To confirm your selection, briefly press the “PROG” key.
• Use the selection wheel to select the valve operating
mechanism/s to be tested.
• Press the “PROG” key to quit the test function.