60
f) Heating pause
Switching off the heating during the summer saves battery
energy and prolongs the service life of the batteries.
During the heating pause the valve is opened completely
and remains in this position. The weekly decalcification cy
cle will, however, still be performed.
Proceed as follows to activate the heating pause:
• Press the “FUNKTION” key to switch to the operating
mode “Manu”.
• Turn the selection wheel clockwise until “On” is displayed
on the LC display.
MO DI
MI DO FR SA SO
Manu
0
6
12
18
24
g) Closing the valve
Select this operating mode if the room is not to be heat
ed at all.
The valve is closed and remains closed.
The valve is only opened if the temperature drops below
5°C (danger of freezing). The weekly decalcification cycle
will still be performed.
Proceed as follows.
• Press the “FUNKTION” key to switch to the operating
mode “Manu”.
• Turn the selection wheel counterclockwise until “OFF is
displayed on the LC display.