Notice:

Be sure to follow the diagrams below when making your own cables. Do not connect the cables  
shield conductor to the ground lug or allow the shield conductor to come in contact with the XLRs  
outer casing. Grounding the shield could cause a short circuit and erratic behaviour.

Special note: 

Line termination:

When longer runs of cable are used,  
you may need to use a terminator on  
the last unit to avoid erratic behaviour.

Using a cable terminator will decrease  
the possibilities of erratic behaviour. 
(3-pin - Order ref: CABL90, 5-pin - Order ref: CABL89)

5-pin XLR DMX connectors:

Some manufactures use 5-pin XLR connectors for data transmission in place of 3-pin. 5-pin XLR fixtures 
may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR connectors in to a 
3-pin line a cable adaptor must be used. The diagram below details the correct cable conversion.

Termination reduces signal transmission 

problems and interference. It is always 

advisable to connect a DMX terminal, 

(resistance 120 Ohm 1/4 W) between pin 2 

(DMX-) and pin 3 (DMX+) of the last fixture.

5-pin XLR (female)

Pin 1: GND (screen)

Pin 2: Signal (-)

Pin 3: Signal (+)

Pin 4: N/C

Pin 5: N/C

3-pin XLR (female)

Pin 1: GND (screen)

Pin 2: Signal (-)

Pin 3: Signal (+)

3-pin XLR (male)

Pin 1: GND (screen)

Pin 2: Signal (-)

Pin 3: Signal (+)

5-pin XLR (male)

Pin 1: GND (screen)

Pin 2: Signal (-)

Pin 3: Signal (+)

Pin 4: N/C

Pin 5: N/C

DMX setup

All manuals and user guides at all-guides.com

Summary of Contents for Endura CW50 COB

Page 1: ...Order code ELUM457 Endura CW50 COB Exterior Fixture User Manual All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 2: ...e unit Do not connect this equipment to a dimmer pack Do not switch the equipment on and off in short intervals as this will reduce the system s life Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that t...

Page 3: ...ht 5kg Order codes ELUM457 280mm 310mm 275mm 245mm 0m 1m 2m 3m 4m 5m 16 Lux 27000 6740 3000 16 1690 1080 The Endura series are heavy duty rental ready IP rated pars made for the most demanding of applications With flicker free operation thanks to a 3 600Hz refresh rate and a multitude of colour and output options the series is perfectly suited for use in concert TV and outdoor applications The fix...

Page 4: ...able 1 x user manual Fuse The Endura CW50 is fitted with an internal mains line fuse The fuse must only be changed by qualified personnel Before opening the fixtures housing or changing the fuse the fixture must be disconnected and isolated from the mains supply Replacement cartridge fuses must be of the same type and rating 20mm Glass T2A 250V When closing the fixture please ensure the seal is co...

Page 5: ...ckout DMX Fail Setting Temp C F Fixture Temperature AutoLock OFF ON Auto Lock Menu Setting Op Time Fixture Run Time DFSE OFF ON Default Factory Settings Channel Value Function 1 000 255 Master dimmer 0 100 1 channel mode 8 bit Channel Value Function 1 000 255 Master dimmer 0 100 2 000 255 Dimmer fine 3 000 255 Strobe slow fast 3 channel mode 16 bit IMPORTANT PLEASE NOTE The LCD display for this fi...

Page 6: ...s and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned t...

Page 7: ...rs Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The diagram below details the correct cable conversion Termination reduces signal transmission problems and interference It is always advisable to connect a DM...

Page 8: ...onment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally safe recycling Business...

Reviews: