background image

Order codes: ELUM135

Virtuoso 2000 Fresnel RGBAL 

User Manual

Summary of Contents for ELUM135

Page 1: ...Order codes ELUM135 Virtuoso 2000 Fresnel RGBAL User Manual ...

Page 2: ...is will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available mains supply voltage is between 100 240V AC 50 60Hz Make sure that the po...

Page 3: ... Fresnel RGBAL Power consumption 235W Fuse T5A 250V Power supply 100 240V 50 60Hz Dimensions 440 x 290 x 445mm Weight 7 6kg Order code ELUM135 0m 2m 3m 4m 5m 1m 45 15 15 Lux FULL ON R G B A L 45 Lux FULL ON R G B A L 51848 13204 14280 2544 14644 26400 6588 1536 1676 267 1752 2980 12871 3301 3570 636 3661 6600 1647 384 419 66 9 438 745 5720 1467 1586 282 1627 2933 732 170 186 29 7 194 331 3217 825 ...

Page 4: ... Function buttons 03 Rotary controls 04 3 Pin DMX input 05 3 Pin DMX output 06 5 Pin DMX input 07 5 Pin DMX output 08 PowerCON input 09 PowerCON output 10 Fuse F5A 250V 11 Hanging bracket 12 Hanging bracket adjustment knobs 13 Carry handle In the box 1 x fixture 1 x filter frame 1 x power cable 1 x user manual 09 10 01 02 12 13 08 04 06 07 05 03 02 11 12 ...

Page 5: ...s the material being used at the installation area and periodic safety inspections of the fixture and installation material If you do not have the relevant experience and or qualifications please do not attempt the installation yourself The installation should be checked annually by a qualified person The eLumen8 Virtuoso 2000 Fresnel RGBAL can be operated in a number of mounting positions as show...

Page 6: ...stallation 1 Fasten the clamp to the fixtures bracket with a bolt and lock nut through one of the mounting holes 2 Mount the fixture onto your truss system via the clamp and tighten to ensure secure 3 Pull the safety cable through the fixture bracket and around the truss 1 2 3 ...

Page 7: ... icon on the top right Pressing the ENTER button once will take the user to the fixtures main menu Using the UP and DOWN buttons you can then navigate between the different options in the main menu Pressing the ENTER button on one of these options allows you to access the sub menu where you can use the UP and DOWN buttons to select option value required Once the option value has been selected pres...

Page 8: ...rols will allow the adjustment of Dimmer CCT and Tint Static colour mode To access static colour mode press the ENTER button and use the UP and DOWN buttons until STATIC is highlighted on the LCD display Press the ENTER button and use the UP and DOWN buttons to select the various options Press the ENTER button and use the UP and DOWN buttons to select between 0 255 Red Green Blue Amber Lime and Zo...

Page 9: ...he LCD display Press the ENTER button and use the UP and DOWN buttons to select the various colours Press the ENTER button to confirm the setting L106 Primary Red R05 Rose Tint L194 Surprise Pink R54 Special Lavender L019 Fire R08 Pale Gold R89 Moss Green R86 Pea Green L213 White Flame Green R377 Iris Purple R80 Primary Blue L202 Half C T Blue L328 Follies Pink R3314 Tough 1 4 Minusgreen L101 Yell...

Page 10: ...ered To do this press the buttons in the following order UP DOWN UP DOWN ENTER The unit will display SEND and the front lens will illuminate yellow whilst exporting to the slave units The front lens will turn green if the export has completed successfully If there are any problems whilst exporting the front lens will turn red Settings menu To access the fixtures settings menu press the MENU button...

Page 11: ...will display RESET and the fixtures settings will return to the factory settings SETTING UPLOAD RESET DIMMER DMX FAIL PERFORMANCE MCON PWM RATE POWER CCT Pass code RESET Dimming speed setting To access the dimming speed setting use the UP and DOWN buttons to select DIMMER Press the ENTER button and use the UP and DOWN buttons to select between DIM4 DIM3 DIM2 DIM1 and OFF Press the ENTER button to ...

Page 12: ...etting This setting allows the performance of the cooling fan to be adjusted To access the fan control setting use the UP and DOWN buttons to select PERFORMANCE Press the ENTER button and use the UP and DOWN buttons to select between LIVE STUDIO and POWER Press the ENTER button to confirm the setting LIVE This is the default performance mode This provides a compromise between both output quality a...

Page 13: ...a transfer OFF MASTER DMX data transfer ON SETTING UPLOAD RESET DIMMER DMX FAIL PERFORMANCE MCON PWM RATE POWER CCT MCON SELF MASTER PWM rate setting refresh rate This setting allows the refresh rate to be adjusted To access the PWM rate setting use the UP and DOWN buttons to select PWM RATE Press the ENTER button and use the UP and DOWN buttons to select between 1200Hz 2400Hz 4000Hz 6000Hz and 25...

Page 14: ... LCD display Press the ENTER button and use the UP and DOWN buttons to between ON and OFF Press the ENTER button to confirm the setting When this is set to ON the passcode will need to be entered each time the display goes off The passcode sequence is UP DOWN UP DOWN ENTER XY Offset There is also an XY OFFSET sub menu within the settings menu this can be set between HIDE default and SHOW When set ...

Page 15: ...etween 1800K 2200K 2700K 3000K 3200K 3500K 4000K 4200K 4500K 5600K 6000K 6500K 7200K and 8000K Press the ENTER button to enter the selected menu Now use the UP and DOWN buttons to select between X FINE and Y FINE these settings will adjust the tint of the CCT Press the ENTER button and use the UP and DOWN buttons to adjust between 200 and 200 Press the ENTER button to confirm the setting Please no...

Page 16: ...M If VERSION is highlighted press the ENTER button and the version number and manufacture date will be displayed If RDM is highlighted press the ENTER button and use the UP and DOWN buttons to select between UID and LABEL If UID is highlighted press the ENTER button and the fixtures RDM UID will be displayed If LABEL is highlighted press the ENTER button and the model number will be displayed INFO...

Page 17: ... 255 8000K CH6 000 009 No function 010 099 Strobe slow fast 100 109 No function 110 179 Lightning strobe 180 189 No function 190 255 Random strobe CH7 000 255 Zoom narrow wide CH8 000 009 Dimming mode set in menu 010 029 No function 030 069 Dimming speed 1 070 129 Dimming speed 2 130 189 Dimming speed 3 190 255 Dimming speed 4 9 channel mode THEATRE Channel Value Function CH1 000 255 Master dimmer...

Page 18: ...0 009 Dimming mode set in menu 010 029 No function 030 069 Dimming speed 1 070 129 Dimming speed 2 130 189 Dimming speed 3 190 255 Dimming speed 4 13 channel mode TOUR Channel Value Function CH1 000 255 Master dimmer 0 100 CH2 000 255 Red 0 100 CH3 000 255 Green 0 100 CH4 000 255 Blue 0 100 CH5 000 255 Amber 0 100 CH6 000 255 Lime 0 100 CH7 000 010 No function 011 020 L106 Primary Red 021 030 R05 ...

Page 19: ...speed 2 130 189 Dimming speed 3 190 255 Dimming speed 4 19 channel mode TR16 Channel Value Function CH1 000 255 Master dimmer 0 100 CH2 000 255 Dimmer fine 0 100 CH3 000 255 Red 0 100 CH4 000 255 Red fine 0 100 CH5 000 255 Green 0 100 CH6 000 255 Green fine 0 100 CH7 000 255 Blue 0 100 CH8 000 255 Blue fine 0 100 CH9 000 255 Amber 0 100 CH10 000 255 Amber fine 0 100 CH11 000 255 Lime 0 100 CH12 00...

Page 20: ...31 4500K 232 235 5600K 236 239 6000K 240 243 6500K 244 247 7200K 248 255 8000K CH15 000 009 No function 010 099 Strobe slow fast 100 109 No function 110 179 Lightning strobe 180 189 No function 190 255 Random strobe CH16 000 255 Zoom narrow wide CH17 000 040 No function 041 060 Auto 1 061 080 Auto 2 081 100 Auto 3 101 120 Auto 4 121 140 Auto 5 141 160 Auto 6 161 180 Auto 7 181 200 Auto 8 201 220 A...

Page 21: ...lowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fix...

Page 22: ...ne a cable adaptor must be used The diagram below details the correct cable conversion 5 pin XLR female Pin 1 GND screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C 3 pin XLR female Pin 1 GND screen Pin 2 Signal Pin 3 Signal 3 pin XLR male Pin 1 GND screen Pin 2 Signal Pin 3 Signal 5 pin XLR male Pin 1 GND screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C DMX setup Termination reduces signal ...

Page 23: ...tures that can be connected is 6 fixtures 240V or 3 fixtures 120V including the first fixture After the maximum number of fixtures are connected a new power run will need to be started Please note Caution should be used when power linking other fixtures to the Virtuoso 2000 Fresnel as the power consumption of other fixtures will vary Fixtures fitted with lamps often require 2 3 times more current ...

Page 24: ...ent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environme...

Reviews: