Operating instructions
Operating instructions
Power CCT setting (correlated colour temperature):
This setting allows the colour temperature to be adjusted.
To access the CCT setting, use the
“UP”
and
“DOWN”
buttons to select
“POWER CCT”
. Press the
“ENTER”
button and use the
“UP”
and
“DOWN”
buttons to select between
“3200K”
,
“4200K”
,
“5600K”
,
“10000K”
, and
“NORMAL”
. Press the
“ENTER”
button to confirm the setting.
SETTING
UPLOAD
RESET
DIMMER
DMX FAIL
PERFORMANCE
MCON
PWM_RATE
POWER CCT
POWER CCT
3200K
4200K
5600K
10000K
NORMAL
Safety lock setting:
To access safety lock setting, press the
“ENTER”
button and use the
“UP”
and
“DOWN”
buttons until
“KEY”
is highlighted on the LCD display. Press the
“ENTER”
button and use the
“UP”
and
“DOWN”
buttons to between
“ON”
and
“OFF”
. Press the
“ENTER”
button to confirm the setting.
When this is set to ON, the passcode will need to be entered each time the display goes off.
The passcode sequence is;
“UP”
,
“DOWN”, “UP”
,
“DOWN”, “ENTER”
.
XY Offset:
There is also an
“XY OFFSET”
, sub menu within the settings menu this can be set between
“HIDE”
(default) and
“SHOW”
. When set to show this will display the XY OFFSET calibrations in some menus.
These calibrations have been set when the fixture was being manufactured to ensure the colour
consistency throughout fixtures from different batches. These settings should NOT be changed.
If these settings are accidentally changed then the
“RESET”
function can be used to reset them to the
defaults (see page 11).
MAIN MENU
MANUAL MODE
STATIC
PRESET COLOR
ADDRESS
RUN MODE
PERSONALITY
SETTING
KEY
CALIBRATION.C
INFO
KEY
ON
OFF
Pass code: