Operating instructions
Operating instructions
Colour calibration setting:
To access the colour calibration setting, press the
“ENTER”
button and use the
“UP”
and
“DOWN”
buttons until
“CALIB.CCT”
is highlighted on the LCD display. Press the
“ENTER”
button.
“Pass code”
will now be displayed and a button press combination will need to be entered.
To do this press the buttons in the following order;
“UP”
,
“DOWN”, “UP”
,
“DOWN”, “ENTER”
.
Use the
“UP”
and
“DOWN”
buttons to select between
“1800K”
,
“2200K”
,
“2700K”
,
“3000K”
,
“3200K”
,
“3500K”
,
“4000K”
,
“4200K”
,
“4500K”
,
“5600K”
,
“6000K”
,
“6500K”
,
“7200K”
and
“8000K”
.
Press the
“ENTER”
button to enter the selected menu. Now use the
“UP”
and
“DOWN”
buttons to select
between
“X FINE”
, and
“Y FINE” (
these settings will adjust the tint of the CCT). Press the
“ENTER”
button
and use the
“UP”
and
“DOWN”
buttons to adjust between
“-200”
, and
“+200”
.
Press the
“ENTER”
button to confirm the setting.
Please note: XY Offset must be set to show to adjust colour calibration (see page 14).