background image

www.prolight.co.uk

MP75 LED Fresnel RGBW

  

User Manual

4

FUSE:
T1A 250V

DMX INPUT

DMX OUTPUT

POWER INPUT:
100-240V~50/60Hz

01

05

03

03

08

02

09

11

12

08

04

06

07

10

Technical specifications

01 - Earth point
02 - LCD display
03 - Function buttons
04 - 3-Pin DMX input
05 - 3-Pin DMX output
06 - Captive power connection

07 - Fuse T1A 250V
08 - Adjustable zoom knob
09 - Barn doors
10 - Filter frame
11 - Hanging bracket
12 - Hanging bracket adjustable knob

In the box: 

1 x fixture 

& 1 x user manual

Summary of Contents for ELUM105

Page 1: ...MP75 LED Fresnel RGBW User Manual Order codes ELUM105 Black Housing ELUM105A White Housing ...

Page 2: ...f in short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available mains supply voltage is between 100 240V AC 50 ...

Page 3: ...refresh rate DMX channels 4 5 or 7 selectable 0 100 dimming 4 dimming curves in both LED and halogen profiles Linear square law inverse square law and S curve 4 push button menu with LCD display Captive power connection 3 Pin XLR input output Filter frame and barn doors included MP75 LED Fresnel RGBW Specifications MP75 LED Fresnel Power consumption 86W Power supply 100 240V 50 60Hz Dimensions 250...

Page 4: ...8 02 09 11 12 08 04 06 07 10 Technical specifications 01 Earth point 02 LCD display 03 Function buttons 04 3 Pin DMX input 05 3 Pin DMX output 06 Captive power connection 07 Fuse T1A 250V 08 Adjustable zoom knob 09 Barn doors 10 Filter frame 11 Hanging bracket 12 Hanging bracket adjustable knob In the box 1 x fixture 1 x user manual ...

Page 5: ...Channel 04 Channel 07 Manual dimming mode Manual R00 G00 Manual B00 W00 Manual R99 G99 Manual B99 W99 Manual DIMMER Sound sensitivity Sound 00 Sound 31 Sound DimCurve Linear DimCurve Square Dimmer curves DimCurve S Curve DimCurve INV Squa DimCurve Built in programs SPEED 00 SPEED 99 1 STATIC 2 CHANGE 4 AUTO 3 FADE LED Halogen selection LampCurv LED LampCurv Halogen LampCurv ...

Page 6: ... RGBW User Manual 6 Operating instructions MENU CONT Display timeout on 30 seconds Display timeout off Display ON Display OFF Display Reset factory settings Default Yes Fixture Time Fixture Time Temp Temperature Version Software version ...

Page 7: ...ne of the 4 5 or 7 DMX channel modes Press the ENTER button to confirm the setting To exit out of any of the above options press the MENU button Channel Value Function 1 000 100 Colour change slow fast 101 200 Colour fade slow fast 201 255 Sound active sensitivity low high 2 000 255 Red 0 100 3 000 255 Green 0 100 4 000 255 Blue 0 100 5 000 255 White 0 100 6 000 030 Linear LED dimming curve 031 06...

Page 8: ...nd use the UP and DOWN buttons to adjust the sound sensitivity level 00 31 Press the ENTER button to confirm your setting 01 low sensitivity 31 high sensitivity To exit out of any of the above options press the MODE button Manual dimming mode To access the manual dimming mode press the MENU button on the rear of the unit to show Manual on the LCD display The unit is now in manual dimming mode Pres...

Page 9: ...ear dimming curve Square LED Square dimming curve INV Squa LED Inverse Square dimming curve S Curve LED S Curve dimming curve Press the ENTER button to confirm the setting To choose between Halogen and LED dimmer curves press the MENU button on the rear of the unit to show LampCurv on the LCD display Press the ENTER button and use the UP and DOWN buttons to set the dimming curve mode required LED ...

Page 10: ...ing DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addr...

Page 11: ...L89 5 pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The diagram below details the correct cable conversion Termination reduces signal transmission problems and interference It is always...

Page 12: ... possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmenta...