A
8A
When igniting the lamp operates at a high pressure and there is a slight risk of arc tube
rupture. The risk increases with age, temperature and improper handling of the lamp. Do
not use the lamp longer than its maximum given lifespan.
Make sure the lamp is located in the center of the reflector for the best projection
5.3 Change The Lamp
Please replace the lamp after 2000 Hours, and clear the lamp running time in the menu.
Disconnect the power cable before starting any servicing.
1. Remove the fixture head covers using a screwdriver (Figure 1).
Figure 1
2. Position the head as Figure 2 and remove the lamp cooling fan at the rear of the head.
Figure 2