Technical data
page 28
ELTROPLAN-REVCON
3.2
General data / application conditions
Area
Values
Permissible temperature range* During transport of the unit:
-25°C...+70°C (to VDE 0160)
During storage of the unit:
-25°C...+55°C (to VDE 0160)
During operation of the unit:
5°C... +40°C without power derating
40°C...+55°C with power derating
Humidity class*
Humidity class F without condensation ( 5% - 85% relative humidity)
Installation height h*
H
≤
1000 m a.m.s.l.
without power derating
1000 m a.m.s.l. < h 4000 m a.m.s.l.
with power derating
Air pressure*
86kPa – 106kPa to VDE0875 part 11 and prEN55082
Degree of pollution
VDE 0110 Part 2 degree 2
Noise immunity
EN 61000-4-4 degree 4
EN 61000-4-2 degree 3
EN 50082-2 criterion A
Insulation strength
Overvoltage category III according to VDE 0110
Packaging
DIN 55468 for transport packaging materials
Type of protection
IP 20
Approvals
CE:
Low-Voltage Directive
*climatic conditions according to class 3K3 (EN 50178 Part 6.1)