Quick guide for TBA firmware V1.070
Description of the displayed parameters
(figure 26)
:
„Q” - charge collected from the discharging battery
„E” - energy collected from the discharging battery
„U” - present voltage of the discharging battery
„Ir” - set discharge current
(correction by means of the adjuster is possible)
„t” - discharge time which increases or decreases depending on the
“Counter Settings”
„G” - the number of enabled resistors enforcing the discharge current
The discharge process is over when the battery reached the final
voltage set in the „Uk” settings
(figure 27)
or when the set time was
over
(figure 28)
.
Blowing is on for 3 minutes after the end of the discharge. The blowing
process allows for faster cooling of resistors.
When the blowing time is over, the display will show the information
on the discharge end reason: „U” - when the „Uk” battery voltage
achieved the set value
(figure 29)
or „t” - when the set discharge time
was over
(figure 30)
.
Press the F1 [End] button to return to the main menu of the tester.
At any moment of the discharge process you may turn off the discharge
current by pressing the [OFF] (red) button.
This possibility should be treated as a temporary halt to the discharge
process.
Press the [ON] (green) button to reactivate the discharge process.
To permanently finish the discharge process, press the F1 [End] button.