
Page
28 of 88
User Manual QT series generation 2.5, ID 2021, rev 3.2, January 14, 2022
Function
Value
Limiting continuous current
1A
Breaking capacity
Max. 48 VA (1A)
Table 8: Cable requirements and recommendations digital and analog systems
Cable parameter
Required/ Recommended
Number of conductors
6 recommended twisted pair.
Cross section
0.5
–
1.5 mm
2
/0.0197
–
0.0591 in
2.
Shield
Not mandatory but is recommended in case the actuator is
placed in conjunction with equipment emitting high levels
of disturbances.
Bus connection of actuators is undoubtedly the most cost-effective
installation method. Eltorque has developed a ground-breaking Hybrid CAN
bus/Power cable especially designed for maritime applications.
Figure 13: Bus connection of actuators
The Eltorque Hybrid Marine Cable combines signal and power cable in a
hybrid cable with maritime type approval. The cable can only be used for
installations with CANopen communication interface box. When this cable is
used, only two cable glands are required, see
Information and Recommended Spare Parts
Figure 14: Hybrid Marine Cable
Further description of the Hybrid Marine Cable is found in the Hybrid Marine
Cable datasheet, Eltorque document ID 1982. The datasheet is available on
www.eltorque.com
–
Products
–
System components.