8. Technical specifications
The current approvals with their supplements can be found at:
http://service.eltex.de.
Bar element
Flame property
Emission tips
Emission rows
Operating
ambient temperature
Ambient humidity
Operating voltage
Short-circuit current
emission tips/ground
Contact protection
High voltage supply
High voltage cable
Assembly
Dimensions
Weight
Air connection
Air pressure
Balancer
(optional)
UL Approval
plastic material (PP, 40 % GF)
UL 94 V-0
stainless steel, injected, current-limited and low
capacitance, non-sparking
2x, one passive, one active, air outlet between
both emission tip rows
0...+80 °C (+32...+176 °F) with compressed air
compressed air temperature max. 30 °C;
0...+60 °C (+32...+140 °F) without compressed air
max. 70%, no dewing permitted
max. 6 kV, 50/60 Hz
0,040 mA
according EN 61140
via Eltex power supplies,
operating voltage max. 6 kV AC
shielded, prefabricated
R55: depending on the unit version: permanently
connected (not exchangeable) or exchangeable,
cable must be ordered separately,
specify cable length and power supply
PR55: additionally glued in, not exchangeable
with assembly material, to be attached to air
blow-in nozzle
see Fig. 5...Fig. 7
R55: approx. 100 g (w/o bracket)
PR55: approx. 200 g
DN8 mm hose (R55) or DN10 mm hose (PR55)
max. 6 bar
Capcity: 0.4 kg - 1.0 kg
Travel: 1600 m
Weight: 630 g
R55: File No. E227156
as shown on
appliance
marking: