3.11 Balancer (optional)

Suspend the balancer from a suitable attachment point. You may also use 
an appripriate tripod or stand.

Adjust the desired spring force.
To avoid unnecessary wear and tear, make sure that the balancer moves 
freely.

Adjusting the spring force

• Make sure that the ropes moves freely over its entire length.
• Hang the ion blower pistol onto the lower hook and secure it against 

inadvertently falling off.

• Check the condition of the rope at regular intervals. If damaged, the 

balancer must be replaced at once for safety reasons.

• Do not use the balancer above its maximum load of 1.0 kg.

Warning!

Do not open the balancer! It holds a set of springs which may result in per-
sonal injury if used improperly.

+

To increase the spring force, turn the rotary button 
anticlockwise.

-

To decrease the spring force, turn the rotary button clockwise.

Summary of Contents for PR55

Page 1: ...Operating Instructions R55 Ion Blower Head PR55 Ion Blower Pistol for AC Operation BA en 2015 1910 F01036y ...

Page 2: ...2 BA en 2015 1910_R55 ...

Page 3: ...o the power supply of series ES5x 14 3 4 Routing the high voltage cable 15 3 5 Connecting compressed air 15 3 6 Routing the air hose 15 3 7 Compressed air properties 16 3 8 Distance setting 16 3 9 Height setting 16 3 10Impact of heat radiation 16 3 11Balancer optional 17 4 Operation 18 4 1 Startup 18 4 2 Operating voltage 18 4 3 Function control 18 5 Maintenance 19 5 1 Cleaning the nozzle inserts ...

Page 4: ...tion Instruction Ion Blower Head R55 30 A 1 1 Electrical Test 31 A 1 2 Mechanical and visual check 31 A 2 Inspection Instruction Ion Blower Pistol PR55 32 A 2 1 Electrical Test 33 A 2 2 Mechanical and visual check 33 Declaration of Conformity 35 ...

Page 5: ...e when going from shingles to copies the ion blower head allows straight edged stacking at high process speeds Also shingle stream separation is greatly improved Charged surfaces binding dirt particles can be efficiently discharged both with the blower pistol and with the blower head removing dust effectively before print finishing The air flow exiting from the hole type nozzles is turbulent Due t...

Page 6: ...4a Air connection for air hose DN8 8 Fishtail nozzle threaded connection in the 9 Filter for PR55 F blower head M12 x 1 5 10 Cable fixing 4b Air connection for air hose DN10 high voltage cable threaded connection in the pistol G 1 4 air supply not included in the delivery Fig 1 Outline drawing R55 ion blower head and PR55 ion blower pistol Z 116124ay Z 116131b_1y B C C ...

Page 7: ...igh voltage cable without flexible tube 1 High voltage cable 2 Plug X 3 Cable gland non detachable 4 Air connection 5 Ion blower housing 6 Hole type or fishtail nozzle 7 Emission tips two row 8 Balancer 9 Adjusting wheel of the balancer Fig 2 Ion blower pistol PR55 with balancer and duo spiral tube with air supply and cable routing R55 Z 116875y ...

Page 8: ...ings hole type nozzle without filter top air connection with balancer PR55 PL without filter top air connection PR55 OL without filter bottom air connection PR55 NL with filter top air connection with balancer PR55 HL with filter top air connection PR55 GL with filter bottom air connection PR55 FL fishtail nozzle without filter top air connection with balancer PR55 PB without filter top air connec...

Page 9: ... in a spi ral tube see Fig 2 A balancer without air and cable routing is available as optional equipment under article no 111569 A design with grease filter is available for ultra clean blowing air The grease filter solely serves to eliminate grease and fat particles from the piston gear of the blower pistol Cleaned apparatuses air must be used as compressed air ...

Page 10: ...h the 5 or 6 kV AC Eltex power supplies which ensure an optimum match with the required operating conditions Other uses are not permitted The manufacturers will not assume any liability and warranty if the units are used improperly or used outside the intended purpose Modifications or changes made to the devices are not permitted Use only original Eltex spare parts and equipment 2 2 Identification...

Page 11: ...high voltage and applies with full power on the plug this may cause a spark dis charge and may lead to a risk of injury Disconnected high voltage plugs are not permitted or have to be grounded see chapter 5 Mainte nance page 19 Check the units and the high voltage cables at regular intervals and before startup for any damage Any damaged components must be repaired or replaced before continuing to ...

Page 12: ...e 19 chapter 6 Troubleshooting page 21 Do not touch the emission tips risk of injury If the high voltage supply is connected reflex responses to electrical irritation can lead to secondary accidents the charging bar as such is safe to touch If contact is made single touch the energy transferred is so low that there is no risk of injury Potential risk for wearers of cardiac pacemakers Moving the ch...

Page 13: ...tective resistors contact protection The function and the appearance of the protective resistors must be inspected at regular intervals The inspection intervals are specified in the accident prevention regulations as amended e g in Germany DGUV V3 Eltex recommend inspection intervals of 6 months The function of the series resistors must be checked using a suitable measuring device The test voltage...

Page 14: ... with a fixed high vol tage cable the high voltage cable is permanently fixed to the blower head Unit version with detachable cable connection Warning Connect or disconnect the high voltage cable only with the power supply switched off Connect the ion blower head to the power supply using the prefabricated high voltage cable Push the high voltage cables into the sockets up to the stop Then the cab...

Page 15: ...t be exposed to tensile stress In applications using movable bars e g film draw strips attach the high voltage cables such that there is no cable movement near the connection point to the power supply 3 5 Connecting compressed air The ion blower head R55 is supplied with an air nipple DN8 and the ion blower pistol PR55 with an air nipple DN10 or a 10 mm plug in connection variant with balancer Att...

Page 16: ...head is required for optimum sheet separation from pile to shingle stream The ionized air flow must be able to penetrate the top paper sheets Adjust the height of the ion blower head via the attachment bracket 3 10 Impact of heat radiation To ensure that the permissible operating temperature is not exceeded the ion blower head resp the ion blower pistol must not be exposed to direct heat radiation...

Page 17: ... entire length Hang the ion blower pistol onto the lower hook and secure it against inadvertently falling off Check the condition of the rope at regular intervals If damaged the balancer must be replaced at once for safety reasons Do not use the balancer above its maximum load of 1 0 kg Warning Do not open the balancer It holds a set of springs which may result in per sonal injury if used improper...

Page 18: ... Operating voltage The blower head and the blower pistol are supplied via the high voltage supply unit The appliances are operated with an optimum operating volt age of 5 resp 6 kV 4 3 Function control Use the Eltex Volt Stick or a glow lamp voltage tester to check the proper function of the emission tips Quote Article No 109136 when ordering the Volt Stick from Eltex Caution To avoid severe damag...

Page 19: ...t by qualified electricians 5 1 Cleaning the nozzle inserts To ensure the trouble free function of the ion blower heads the surface from which the emission tips and the compressed air exit must be clean and dry at all times Dirty blower heads must be cleaned with a suitable solvent cleaning gasoline and a brush with soft plactic bristles To pre vent the air exit holes from clogging up with dirt du...

Page 20: ...e g in Germany DGUV V3 Eltex recommend inspection intervals of 6 months The function of the series resistors must be checked using a suitable measuring device The test voltage must be 1 000V The measured resis tance between the high voltage connection and the individual emission tip must not fall below 104 MOhm and not exceed 156 MOhm Please note that only one of the two emission tip rows is conne...

Page 21: ...table solvent cleaning gasoline Caution Allow the solvent to evaporate com pletely before restarting the unit Do not soak the blower head in solvent Short circuit in the high voltage cable If required exchange the high volt age cable at the R55 ion blower head In the event of defective high voltage cables at the R55 ion blower heads with fixed cable connection and at the PR55 ion blower pistol ple...

Page 22: ... the operating and assembly instructions spe cified by Eltex have been observed The warranty period begins on the date of delivery In the event of defects occurring during the warranty period the units or defective components will be repaired at Eltex Defective components will be replaced and installed free of charge If repairs are required at the customer s premises the costs for sending a techni...

Page 23: ...air outlet between both emission tip rows 0 80 C 32 176 F with compressed air compressed air temperature max 30 C 0 60 C 32 140 F without compressed air max 70 no dewing permitted max 6 kV 50 60 Hz 0 040 mA according EN 61140 via Eltex power supplies operating voltage max 6 kV AC shielded prefabricated R55 depending on the unit version permanently connected not exchangeable or exchangeable cable m...

Page 24: ... 27 7 Ion blower head radial with fishtail nozzles R55 RB 1 8 4 7 9 5 13 5 18 1 22 1 Ion blower head axial with hole type nozzles R55 AL 2 1 5 8 11 0 15 9 20 5 24 5 Ion blower head axial with fishtail nozzles R55 AB 1 0 2 8 5 5 8 3 11 2 14 2 Ion blower pistol with hole type nozzles PR55 _L 1 0 2 7 5 0 7 3 9 6 11 5 Ion blower pistol with fishtail nozzles PR55 _B 0 9 2 5 4 8 7 1 9 2 11 1 ...

Page 25: ...25 9 Dimensions and brackets Fig 5 Ion blower head R55 radial and axial connection design with standard bracket Z 116128y Fig 6 Ion blower head R55 radial and axial connection design with universal bracket Z 116125y DB DB ...

Page 26: ...26 BA en 2015 1910_R55 Hole type nozzles Fishtail nozzles Filter Fig 7 Ion blower pistol PR55 with or without air filter Z 116131_2y Fig 8 Z01163y ...

Page 27: ... length KE ZY___ High voltage cable with flexible tube from power sup ply ES24 or distributor ESVY61 _Z to blower heads R55 specify cable length KE YW___ Plug L Kit for cutting high voltage cable to size without flexible tube for power supply ES5x 101366 Plug S Kit for cutting high voltage cable to size with flexible tube for power supply ES5x 103289 Plug X Kit for cutting high voltage cable to si...

Page 28: ...gh voltage cable and plug specify cable length and plug typ R55 RB6E_ _ _ _ Protective rubber edging for blower head and pistol 103532 Plastic blower pistol with top air connection 109683 Plastic blower pistol with bottom air connection 109682 Adaptor pistol head 109575 Sealing for adaptor article no 109589 112138 Filter component assembly for PR55 113119 Cover for filter 108415 Air connection for...

Page 29: ...200 Balancer 111569 Retrofit option balencer with ion blower head R55 with hole type nozzle without air filter and plug S 116807 Retrofit option balencer with ion blower head R55 with hole type nozzle without air filter and plug Z 116808 Retrofit option balencer with ion blower head R55 with fishtail nozzle without air filter and plug S 116809 Retrofit option balencer with ion blower head R55 with...

Page 30: ...work regulations e g DGUV V3 for Ger many Eltex recommend a test interval of 6 months 1 Ion Blower Head 1 1 Hole type nozzles 1 2 Fishtail nozzles 2 1 Air connection axial 2 2 Air connection radial 3 Connector base 4 High voltage connection 5 HIgh voltage plug Ion Blower Head side 6 Protective hose 7 High voltage cable 8 High voltage plug Power Supply side 9 Emission tips Z 115343y ...

Page 31: ...r 0 3 0 5 bar must be switched on during cleaning Warning Risk of deflagration Allow the solvent to evaporate completely before restrting the unit Caution Do not damage the emission tips when cleaning Check the compressed air supply line and the compressed air connec tion 2 1 2 2 for any damage deformation material or surface condi tion and for firm connection The high voltage cable 7 must be rout...

Page 32: ...health and safety at work regulations e g DGUV V3 for Ger many Eltex recommend a test interval of 6 months 1 Ion Blower Head 1 1 Emission tips 2 High voltage cable 2 1 High voltage connection 3 Protective hose 4 Coupling link 5 1 Hole type nozzle 5 2 Fishtail nozzle 6 Blower pistol 6 1 Operating lever 7 Air connection DN10 bottom or top 8 Filter Z 114212y ...

Page 33: ... tion at the air nipple or the plug connection 7 of the ion blower pistol for any damage deformation and for firm connection For appliance versions fitted with air filters 8 check the filter insert for any dirt and grime and if required exchange the filter insert The high voltage cable 2 must be routed to make sure that it does not make contact with moving machine parts Avoid mechanical deforma ti...

Page 34: ...34 BA en 2015 1910_R55 ...

Page 35: ......

Page 36: ... mbH Blauenstraße 67 69 79576 Weil am Rhein Germany Phone 49 0 7621 7905 422 eMail info eltex de Internet www eltex de Eltex offices and agencies The addresses of all Eltex agencies can be found on our website at www eltex de Z01007y ...

Reviews: