98
User Manual, Part IV
Subscriber access/aggregation node МA4000-РХ
28.4
ONT Configuration Procedure
Figure 35 shows steps of ONT configuration.
Fig. 35—ONT Configuration Procedure
Step 1. Prior to proceed to ONT configuration, add the ONT into an OLT configuration. For an ONT
to be added and configured, it does not need to physically connected to OLT. You can view the list of
unactived ONTs with the help of the
show interface ont unactivated
command:
ma4000# show interface ont 0/0/0 unactivated
Slot 0 GPON-port 0 has no unactivated ONTs
Slot 0 total ONT count: 0
Step 2. To specify ONT settings, go to the corresponding view with the help of the interface ont
command. Specify ONT serial number, password, or their combination.
ma4000# configure terminal
ma4000(config)# interface ont 0/0/0
ma4000(config)(if-ont-0/0/0)# serial ELTX5C00008C
ma4000(config)(if-ont-0/0/0)# password 0000000000
Step 3. Apply the changes by using the
do commit
command.
ma4000(config)(if-ont-0/0/0)# do commit
Step 4. OLT entry configuration has pre-defined ONT profiles which will be automatically assigned
to ONT. View the ONT configuration with the help of the
do show interface ont 0/0/0 configuration
command.