8
Elterm M.M.Kaszuba Sp.J., ul. Przemysłowa 5, 86-200 Chełmno
www.elterm.pl
Dimensions:
Troubleshooting:
Problem
Cause
Solution
Water leakagefrom connections.
A. Not properly screwed connections.
B. Lack of seal.
A. Try to screw properly.
B. Exchange seal.
LED is not working.
A. Lack of electricity.
B. Damaged diode.
A. Connect electricity.
B. Exchange diode (service).
Buttons does not work.
A. Water supply is turned off.
B. Too low water pressure.
C. Device malfunction.
A. Turn water supply on.
B. Check water pressure.
C. Service required.
Water is too hot.
A. Too high water temperature setting.
B. Too low water pressure.
A. Decrease water temperature setting.
B. Increase water flow.
Water is too cold.
A. Too low water temperature setting.
B. Too high water demand compared
with device power.
A. Increase water temperature setting.
B. Decrease water flow (e.g. use only 1
intake point at one time).
Water pressure is dropping.
Mesh filter is filled.
Check and clean filter.
No water heating.
Thermic switch was activated.
Take casing off and press reset button.
Display shows E1.
Water temperature exceeded 67°C.
Reduce temp.
Increase water supply.
Display shows E2.
Leakage.
Contact service.
Display shows E3.
Sensor malfunction.
Contact service.
Any attempt to fix device outside authorized service causes
warranty loss
!