Elterm Grzejemy jak Kawaleria Admiral Series Operating And Assembly Manual Download Page 6

Elterm M.M.Kaszuba Sp.J., ul. Przemysłowa 5, 86-200 Chełmno      

www.elterm.pl

 

 

 

Water connection:

 

 

1.

 All water pipes and other accessories must be in accordance with all current regulations and laws.

 

2.

 Device has to be connected vertically (connections from bottom side). Horizontal placement is forbidden. 

Blue connection is for cold water inlet, red one for hot water outlet.  

3.

  Flush  the  system  through  completely  by opening  the  hot  tap  on the water  heater  circuit  furthest  away 

from the heater. Allow all air and debris to pass before closing the hot tap.  

4.

 Remember to use rubber gaskets on water connections.  

5.

 On cold water inlet, rubber gasket should be equipped with mesh net. All connections need to be checked 

for tightness. 
 

Use:

 

Flow  heater  starts  operation  when  water  flow  sensor  detects  demand  for  hot  water  (eg.    starting  a 

shower) – only then device turns on and starts to consume electrical energy). Device is turned off instantly 
when demand for hot water stops. It is possible to set required water temperature level, what additionally 
reduces total energy consumption.  
 

Flow heaters are equipped in overheating safety feature. When water temperature exceeds 67°C (7,5 kW) 

and  72°C  (12  -  21  kW)  device  will  enter  into  pause  mode  in  order  to  avoid  scales  deposition.    It  will  be 
indicated by "

E1

" shown on display. Device will return to standard mode after temperature cools down to 

58°C.  Automatics  also  monitors  current  loss,  which  when  detected  is  indicated  by  "

E2

"  shown  on  display. 

"

E3

" is shown when temperature sensor has been damaged.   

 

Admiral

  also  protects  build-in  heating  element  from  overheating  –  electric  supply  is  turned  off  when 

heating element temperature reaches 95°C (7,5 kW) and 90°C (12 - 21 kW). In case this protective system is 
activated, one should remove external case and press 

RESET 

button. 

 

Control:

 

1. 

Open the water faucet for a few minutes until water flow is continuous and all air is purged from water 

pipes, after turning water off turn on power supply.

 

2. 

With vented installation and turned on power supply, 

Admiral

 can be used. Press      , and open running 

water to ensure flow rate of more than 3,2 l/min for flow heaters 12-21 kW and more than 2 l/min for flow 
heater 7,5 kW. 

3. 

In order to turn device off simply stop using hot water.

 

4. 

Use        and         buttons to change requested temperature. 

 

5.

  During  standard  operation  display  shows  current  water  temperature,  by  pressing                buttons                                                                      

set temperature is visible. 

6.

 Device is equipped in safety valve, which will be triggered automatically when inside pressure exceeds 1,2 

Mpa. 

Water  connection  need  to  be  performed  using  elastic  hoses  with  gasket.  Do  not  use  teflon  or 
oakum for that purpose. Please pay special attention while making water connection,  rotating or 
breaking connection may cause irreparable damage to the device. 

Summary of Contents for Grzejemy jak Kawaleria Admiral Series

Page 1: ...ul Przemysłowa 5 86 200 Chełmno www elterm pl Operating and assembly manual Electric instantaneous flow heater Admiral build in AsC and AsC W electric heating boilers or sold separately Available power 7 5kW 12kW 15kW 18kW 21kW ...

Page 2: ...ulation material it is natural if there might be a bit of smell or green blue smoke when the unit is used for the first time 10 In case of cable wire damage you must contact qualified electrician to replace it with a new wire s 11 Please flush the system through completely by opening the hot tap on the water heater circuit furthest away from the heater Allow all air and debris to pass before closi...

Page 3: ...shower Water is not pre heated and stored but heated directly when needed As a consequence no energy is lost in the process Admiral has state of the art patented heat exchanger solution which eliminates scale deposition most common issue with standard flow devices with build in heaters Water is completely separated from live components what ensures high durability and 100 safety Use Electric insta...

Page 4: ... the device is not mechanically damaged and complete 2 Do not install in premises where temperature falls below 0 C 3 Compare your installation with device requirement power allocation supply voltage water pressure earth wires cross section proper fuses both over current and differential current etc 4 Device needs to be earthed 5 Main power circuit needs to be protected both over current and diffe...

Page 5: ...refully before removing the front cover Once your product has been fixed in accordance with the diagrams above please connect your product to the mains water supply using a 1 2 tap pipes to the blue connection of the unit Electrical works 1 The installation must only be carried out by qualified electrician in accordance with all regulations 2 The unit must be properly earthed and proper fuses need...

Page 6: ...1 shown on display Device will return to standard mode after temperature cools down to 58 C Automatics also monitors current loss which when detected is indicated by E2 shown on display E3 is shown when temperature sensor has been damaged Admiral also protects build in heating element from overheating electric supply is turned off when heating element temperature reaches 95 C 7 5 kW and 90 C 12 21...

Page 7: ...ed by any regular maintenance procedures please ensure consistent water flow it is recommended for the following maintenance 1 Periodically remove scale and dirt that may build up at the aerator of the faucet or in the shower head Please periodically clean inlet strainer and the shower to keep a free water flow 2 There is a built in meshed gasket screen at inlet connection which should be cleaned ...

Page 8: ...Too high water temperature setting B Too low water pressure A Decrease water temperature setting B Increase water flow Water is too cold A Too low water temperature setting B Too high water demand compared with device power A Increase water temperature setting B Decrease water flow e g use only 1 intake point at one time Water pressure is dropping Mesh filter is filled Check and clean filter No wa...