Elterm Grzejemy jak Kawaleria Admiral Series Operating And Assembly Manual Download Page 1

Elterm M.M.Kaszuba Sp.J., ul. Przemysłowa 5, 86-200 Chełmno      

www.elterm.pl

 

 

 

 

 

 

 

 

 

 

Operating and assembly manual: 

Electric instantaneous flow heater “Admiral” 

(build in AsC and AsC-W electric heating boilers or sold separately) 

 

 

 

  

 

 

 

 

 

 

 

 

Available power: 7,5kW; 12kW; 15kW; 18kW; 21kW

 

Summary of Contents for Grzejemy jak Kawaleria Admiral Series

Page 1: ...ul Przemysłowa 5 86 200 Chełmno www elterm pl Operating and assembly manual Electric instantaneous flow heater Admiral build in AsC and AsC W electric heating boilers or sold separately Available power 7 5kW 12kW 15kW 18kW 21kW ...

Page 2: ...ulation material it is natural if there might be a bit of smell or green blue smoke when the unit is used for the first time 10 In case of cable wire damage you must contact qualified electrician to replace it with a new wire s 11 Please flush the system through completely by opening the hot tap on the water heater circuit furthest away from the heater Allow all air and debris to pass before closi...

Page 3: ...shower Water is not pre heated and stored but heated directly when needed As a consequence no energy is lost in the process Admiral has state of the art patented heat exchanger solution which eliminates scale deposition most common issue with standard flow devices with build in heaters Water is completely separated from live components what ensures high durability and 100 safety Use Electric insta...

Page 4: ... the device is not mechanically damaged and complete 2 Do not install in premises where temperature falls below 0 C 3 Compare your installation with device requirement power allocation supply voltage water pressure earth wires cross section proper fuses both over current and differential current etc 4 Device needs to be earthed 5 Main power circuit needs to be protected both over current and diffe...

Page 5: ...refully before removing the front cover Once your product has been fixed in accordance with the diagrams above please connect your product to the mains water supply using a 1 2 tap pipes to the blue connection of the unit Electrical works 1 The installation must only be carried out by qualified electrician in accordance with all regulations 2 The unit must be properly earthed and proper fuses need...

Page 6: ...1 shown on display Device will return to standard mode after temperature cools down to 58 C Automatics also monitors current loss which when detected is indicated by E2 shown on display E3 is shown when temperature sensor has been damaged Admiral also protects build in heating element from overheating electric supply is turned off when heating element temperature reaches 95 C 7 5 kW and 90 C 12 21...

Page 7: ...ed by any regular maintenance procedures please ensure consistent water flow it is recommended for the following maintenance 1 Periodically remove scale and dirt that may build up at the aerator of the faucet or in the shower head Please periodically clean inlet strainer and the shower to keep a free water flow 2 There is a built in meshed gasket screen at inlet connection which should be cleaned ...

Page 8: ...Too high water temperature setting B Too low water pressure A Decrease water temperature setting B Increase water flow Water is too cold A Too low water temperature setting B Too high water demand compared with device power A Increase water temperature setting B Decrease water flow e g use only 1 intake point at one time Water pressure is dropping Mesh filter is filled Check and clean filter No wa...