background image

Function rotary switches

 behind the RV-rotary switch to show the 
reversal time.

RV

 = The 

time delay

 (delay time RV) is 

set by the top rotary switch. If the FSB is 
in the UP or DOWN position the selected 
delay time runs (elapses); at time-out the 
device changes  auto matically to STOP. 
Therefore, the time  delay must be chosen 
at least as long as the shading element 
or roller shutter will need to move from 
one limit position to the other. The LED 
indication for the delay time RV is located 
behind the rotary switch RV.

When one or several wireless window/
door contacts FTK or Hoppe window 
handles are taught-in, 

a lock-out pro-

tection is set up while the door is open 
which prevents Central down and Scene 
down.

The red LED 

accompanies the teach-in 

process and indicates control commands 
in operation by flashing briefly.

The green LED 

flashes briefly when a 

confirmation telegram is sent.

All sensors must be taught in in the 
actuators so that they can detect and 
execute commands.

Teaching-in actuator FSB71-2x-230 V

Before starting the teach-in pro-
cess, connect the device and plug 
in the power supply unit.

The teach-in memory is empty on delivery 
from the factory. If you are unsure whether 
the teach-in memory contains something 
or not, 

you must fi rst clear the memory 

contents completely: 

Set the middle rotary switch to CLR. The 
LED fl ashes at a high rate. Within the 
next 10 seconds, turn the upper rotary 
switch three times to the right stop (turn 
clockwise) and then turn back away from 
the stop. The LED stops fl ashing and 
goes out after 2 seconds. All taught-in 
sensors are cleared. 

Clear individual taught-in sensors 

in the 

same way as in the teach-in procedure, 
except that you set the middle rotary 
switch to CLR instead of LRN, and 
 operate the sensor. The LED previously 
fl ashing at a high rate goes out.

Clear device confi guration:

Set the middle rotary switch to CLR. The 
red LED fl ashes at a high rate. Within the 
next 10 seconds, turn the upper rotary 
switch six times to the left stop (turn 
 anticlockwise) and away again. The red 
LED stops fl ashing and goes out after 
5 seconds. The factory settings are 
 restored.

Teaching-in sensors:

1.  Set the top rotary switch to the 

required teach-in function:

   

10

 = Teach in direction pushbutton 

Motor 1.

 

 20

 = Teach in universal pushbutton 

and FTK Motor 1.

 

 30

 = Teach in direction pushbutton 

Motor 2.

 

 40

 = Teach in universal pushbutton 

and FTK Motor 2.

 

 60

 = Teach in central control push-

buttons Motors 1 and 2 without priority.

 

 90

 = Teach in central control push-

buttons Motors 1 and 2 with priority.

!

Typical connection

Teaching-in wireless sensors in 
wireless actuators
All sensors must be taught-in in the 
actuators so that they can detect and

L
N

PE

4    3

2    1

M

M

Function rotary switch below
AUTO 1

 = In this position, the local 

 advanced automatic reversing system 
for Venetian blinds

 is activated. When a 

universal pushbutton or a direction 
push button are used for control a double 
 impulse activates a slow  rotation in the 
opposite direction, which can be stopped 
with a further impulse. 

AUTO 2

 = In this 

position, the local  advanced automatic 
reversing system for Venetian blinds is 
completely  switched off. 

AUTO 3

 = In 

this position, the local push buttons act 
static at fi rst, thus, allow 

 reversal of 

Venetian blinds

 by operating pushbuttons. 

They only switch to dynamic  after 
0.7 seconds continuous operation. 

AUTO 4

 = In this position, the local push-

buttons act only static (ER function). The 
time delay RV (wiping time) of the upper 
rotary switch is active. Central control is 
not possible.

▲▼

▲ 

(UP) and 

▼ 

(DOWN) of the 

lower rotary switch are the positions for 

manual control.

 Manual control has 

 priority over all other control commands.

WA

 = 

Automatic reversal

 for Venetian 

blinds and awnings is controlled by the 
middle rotary switch. 0 = OFF, otherwise 
from 0.3 to 5 seconds ON with the 
 selected reversal time. In this case, it is 
only for DOWN that the  direction is 
 reversed on time-out of the time lag 
 selected by the top rotary switch, e.g. to 
extend awnings or set Venetian blinds to 
a defi ned position. A LED is located 

Technical data

Rated switching capacity  4 A/250 V AC
each contact

Inductive load 

650 W

1)

cos 

M

 = 0.6/230 V AC 

inrush current 

d

35 A

Standby loss (active power) 

0.8 W

1) 

Sum of both contacts 1000 W max.