Use the data transformer DAT71 to create 
a link to a PC running the PCT14 soft-
ware.

Confi gure FSB71:

The following points can be confi gured 
using the PC PCT14 tool:

   Teach in buttons and wireless Hoppe 

window handles with single or double 
click.

  Behaviour with central commands

 Lock-out protection

  Runtimes for shading scenes

  Parameters for operating with FAH60

  Parameters for operation of FWS61

  Add or change sensors

When an actuator is ready for 
teach-in (the LED fl ashes at a 
low rate), the very next incoming 
signal is taught-in. Therefore, 
make absolutely sure that you 
do not activate any other sensors 
during the teach-in phase.

Cable fi xation

The cable must be fastened with standard 
cable ties (width < 3,6 mm).

ELTAKO GmbH hereby declares that the 
products that relates to this operating 
manual, are in compliance with the 
 essential requirements and other rele-
vant provisions of directive 1999/5/EC. 

A copy of the EU declaration of confor-
mity can be requested at the address 
below.