G E N E R A L   D E S C R I P T I O N  

 

_________________________________________________________________________________   

GsmAlarm-420                                                                                                           Software ver. 1.05 
 

- 2 -

Remote  control  and  monitoring  device  GsmAlarm-420  has  built-in  radio  transmitter  operating  on 
GSM900 and GSM1800 networks.  
Do not use the device where it can cause interferences and danger.   
Do not arrange the device close to medical equipment and appliances.  
Do not use the device in explosive environment. 
Device is not resistant to moisture, chemical materials or mechanical damage.  
Don’t attempt to personally repair the system. 
System label is on the bottom side of the device. 
 
 

This symbol on the product or on its packaging means that your electrical and electronic 
equipment should be disposed at the end of life separately from your household wastes. 
There are separate collection systems for recycling in EU. For more information, please 
contact the local authority or the dealer where you purchased the product. 

 

 

 

The device compliance to RoHS Directive.                                                                                

 
 
 
1.2.

 

PACKAGE CONTENT 

 
GsmAlarm-420 main board ........................................................................... Qnty   1 
GSM antenna with magnetic fix and 2 m lead cable ...................................... Qnty   1 
Microphone with 1,5 m lead cable ................................................................. Qnty   1 
Load resistors 2,2k

 ±5% ............................................................................. Qnty   6 

Clamping cable for accumulator connection .................................................. Qnty   1 
User‘s manual ................................................................................................ Qnty   1 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for GsmAlarm-420

Page 1: ...r connection 3 programmable outputs for remote control Option to switch the protection mode on off by short free call 5 users are informed on the protected unit 250 users able to control the gate or electromagnetic lock by short free call Info carrying SMS on the state of each sensor number of triggers system mains voltage GSM signal strength Option to connect siren Option to connect external mic ...

Page 2: ...5 Programming 11 5 1 User Number Programming with Standard Mobile Phone 11 5 2 User Number Programming with SMS 12 5 3 System Parameter Programming with SMS 14 5 3 1 Protected Zones Z1 Z5 Parameter Programming 14 5 3 1 1 Parameter M 15 5 3 1 2 Parameter A 15 5 3 2 Programming of Output C1 C2 BELL and Common System Parameters E F T U 16 5 3 2 1 Output C1 C2 and BELL Operation Mode 17 5 3 2 2 Parame...

Page 3: ...tisfy the safety requirements of LST EN 60950 1 standard External power supply can be connected to AC mains only inside installation room with automatic 2 pole circuit breaker capable of disconnecting circuit in the event of short circuit or over current Open circuit breaker must have a gap between connections of more than 3mm and the disconnection current 5A Only a qualified specialist possessing...

Page 4: ...Don t attempt to personally repair the system System label is on the bottom side of the device This symbol on the product or on its packaging means that your electrical and electronic equipment should be disposed at the end of life separately from your household wastes There are separate collection systems for recycling in EU For more information please contact the local authority or the dealer wh...

Page 5: ...e system can indicate entrance exit with an audio signal if the miniature sound signalization element is connected to system A user will receive an SMS message if GSM connection was lost for over 30 seconds The message is sent only when the protection mode is turned on The device suites perfectly for remote control of automated gates fences and electromagnetic door locks In order to open a gate a ...

Page 6: ...mode or in a zero one mode see Ch 5 3 1 2 The loaded input mode is recommended to be used for protection of premises In this case all the inputs have to be loaded with 2 2kΩ resistors The system becomes triggered both when the monitored input circuit is broken as well as when it is short circuited In the second case the system is triggered after breaking or short circuiting of the monitored input ...

Page 7: ...3 2 1 C1 C4 equivalent diagram 2 4 OUTPUT BELL The BELL output is used to connect audio siren or extra commutated device see Ch 4 1 and 4 2 Commutated current may reach 0 6 A max Equivalent diagram of BELL OUTPUT 2 5 OUTPUT AUX AUX output is used to supply power external devices fire motion sensors and is short circuit protected This output has voltage 13 7 V or 6 8V depending on the system parame...

Page 8: ...nnection Blinks once short break after Poor connection 3 2 Z1 Z4 INPUT STATUS INDICATOR Indicator state Explanation Out Input is not triggered Continuously On Input is triggered 3 3 MODE SYSTEM OPERATION MODE INDICATOR Indicator state Explanation Out No power supply or system failure Continuously On System is operative disarmed no zone sensors have been triggered On with short breaks System is ope...

Page 9: ... 4 1 INSTRUCTION FOR PREMISES PROTECTION INSTALLATION System should be assembled in metal housing 7TRP20 as recommended Antenna is fixed on the top of outer side of metal housing Cable Hole Housing Fixture Holes 4 x 5 mm Metal Housing 7 TRP20 SIGNAL Z1 Z2 Z3 Z4 MODE ALARM G S M A L A R M 4 2 0 ANTENNA CONNECTOR RED BLUE RESERVE BATTERY AC 12V 1 2Ah CT1 2 12 SAUGIKLIS POWER SUPPLY TRANSFORMER T 0 1...

Page 10: ...in a prominent place LED state indicates system operation mode status if all protected zones are closed before switching on armed mode User can arm disarm system with short call from user mobile phone parameter F should be F51 or F41 see Ch 5 3 2 3 Please note if trying to call the system in alarm state deactivation is not possible therefore it is recommended to use switch ON OFF designed for acti...

Page 11: ...ic interference vehicle computer conditioner block of relays Avoid mounting system unit directly onto metal parts of vehicle to prevent accumulation of condensate in the system unit Mount GsmAlarm 420 in a way wire connectors are going from the bottom side of the unit Avoid placing wires adjacent to moving or hot parts of vehicle Reserve 6V battery must be accurately fixed close to GsmAlarm 420 de...

Page 12: ...M card into GsmAlarm 420 SIM card holder turn system power on then wait till indicator SIGNAL will start to blink periodically and indicator MODE will be constantly alight In case SIGNAL is constantly alight check if SIM card s PIN code request is off and GSM antenna is connected GSM signal quality can be evaluated according the blinking frequency of SIGNAL indicator Connection is very good if it ...

Page 13: ...s used only for gate control it is not necessary to program ALRNR1 ALRNR5 Up to 250 user numbers with the possibility to control the outputs C1 C2 and BELL with a short call can be programmed in this case Any name can be ascribed to user Output operation mode has to be M04 or M05 see Ch 5 3 2 1 After programming of user numbers programmed system parameters names of inputs and outputs see Ch 5 3 5 ...

Page 14: ...after the colon c Spaces must follow the password and each phone number d It is recommended to enter user numbers with international code e g 123 It is not necessarily to send all user numbers E g in order to programme only the first user number send the following SMS A A A A A A A A A L R N R 1 3 7 0 6 1 2 3 4 5 6 7 8 9 Receipt and decrypting of the SMS by GsmAlarm 420 is confirmed by blink of in...

Page 15: ...elete the extra user number send to GsmAlarm 420 the following message A A A A A A A A D E L N R 3 7 0 1 2 3 4 5 6 7 8 9 1 D E L N R 3 7 0 1 2 3 4 5 6 7 8 9 2 D E L N R 3 7 0 1 2 3 4 5 6 7 8 9 3 Specified numbers will be deleted and user receives the confirming SMS DELET 3701234567891 DELET 3701234567892 DELET 3701234567893 Up to 8 user numbers might be deleted with one SMS message In order to rec...

Page 16: ...ith frequent blinking of MODE indicator and sends SMS message including input parameters Z1 Z5 Received message will look as follows AAAAAAAA Z1 M70T20A20 Door Z2 M70T00A20 Windows Z3 M70T00A20 Movement Z4 M71T00A20 Fire Z5 M02T00A20 OFF AAAAAAAA password Z1 protected zone input number M70 parameter defines system response to the violation of protected zone and which users are informed if certain ...

Page 17: ...ystem switches alarm on with no respect to armed mode ON OFF siren operates constantly delay time is ignored Fire zone mode 24 hour input siren is operating with interruptions Zone ON OFF Mode designated to turn armed mode on off Follow zone After violation of this zone alarm goes on immediately if other zone with delay isn t violated If firstly zone with delay is violated for example doors are op...

Page 18: ...inutes OutC1 OutC2 and Siren programmable output names A user can change the name under his own discretion Maximum number of name characters 10 PR E24F11L01T20U12 PR command for programming the common system parameters E24 the method to inform the user about activation deactivation of the armed mode The user can be informed by a short call or an SMS message see Ch 5 3 2 2 F11 system response to in...

Page 19: ...on of the programmed period M05 Control by short call with number recognition function gate control mode This mode operates analogue to M04 thus it is activated only if short call number coincides with programmed numbers M06 Siren mode Valid only for output BELL C3 M07 Siren mode with audible confirmation After arming one short audible sound is heard After disarming two short audible sounds are he...

Page 20: ...om ALRNR1 ALRNR5 thus the calling number is in SIM card gate control mode system answers the call after 3 4 signals and user can control the system with DTMF instructions Call automatically cancelled after 1 minute passes Note If several functions have to be operative sum of the numbers is used E g for all three X functions to be active X value must be 7 1 2 4 7 5 3 2 4 PARAMETER U RESERVE BATTETY...

Page 21: ...arameters back to GsmAlarm 420 device Setup of user telephone numbers is described in Ch 5 5 1 5 2 and 7 3 ADDNR DELNR NRLIST Important Two identical telephone numbers cannot be programmed under different names The command NRLIST is used for review of the numbers see Ch 5 2 6 RESETTING SYSTEM PARAMETERS TO FACTORY DEFAULTS In order to return all system parameters back to default settings connect c...

Page 22: ...ive SMS with programmed parameters c change parameter U12 into U06 and send the same SMS to GsmAlarm 420 Input parameters Input Name Parameter M Delay time T Parameter A Z1 Door M70 T00 sec A00 Z2 Bonnet M70 T00 sec A00 Z3 Boot M70 T00 sec A00 Z4 Shock M70 T00 sec A00 Z5 ON OFF M03 T00 sec A00 Output parameters Output Name Parameter M Operation time T C1 OutC1 M02 T05 sec C2 OutC2 M05 T05 sec C3 B...

Page 23: ...s the call and in the case number is accepted switches the controlled device on or off GsmAlarm 420 responds to area violations only in armed mode except the case when the input operates in 24 hour mode Armed mode can be switched on only if all the areas are untriggered MODE LED is permanently on If MODE is on with short breaks some of the areas is active open window doors etc Armed mode can be sw...

Page 24: ...ree tone confirmation signals If given instruction has already been executed earlier e g you want to switch on the commutator that is already ON user hears one tone confirming signal Speech mode can be activated in two ways user answers when GsmAlarm 420 calls or user calls and waits for GsmAlarm 420 to answer 3 4 call signals In this case relevant parameter F has to be programmed see Ch 5 3 2 3 o...

Page 25: ...output C1 C2 and BELL parameters NRINFO Request to send SMS message with user numbers of security system ALRNR1 ALRNR5 PASSW SMS password change instruction ALRNR1 ALRNR2 ALRNR3 ALRNR4 ALRNR5 System users number programming instructions ADDNR Gate control mode users number programming instructions DELNR Gate control mode users number erasing instructions NRLIST Request to send SMS message messages...

Page 26: ...ufacturing date dated on security system identification label Warranty is not valid if system is reconstructed wrongly assembled used not on purpose mechanical chemical electric damage and in other cases that are not related with GsmAlarm 420 manufacturing defects are seen If security system is not operating properly or breaks down for guarantee or post guarantee service please contact company tha...

Page 27: ...C 12V Output voltage in car protection mode DC 6V Maximum current 1 A max Short circuit protection triggering current 2 A max SIREN OUTPUT BELL C3 Maximum current 0 6 A max Output active siren is on Connected to GND Output non active siren is off Open contact PROGRAMMABLE OUTPUTS C1 C2 Maximum current 150 mA max Output active Connected to GND Output non active Open contact INPUTS Z1 Z5 Load resist...