2.2. Electrical insulation
Control gear with eSMART technology has been designed in accordance with the EN 61347-1 and EN 61347-2-13
safety standards for double or reinforced insulation against electric shocks resulting from contact with accessible
parts.
The insulation between the primary and secondary circuits, as well as between every circuit and the functional earth,
is set out in the following table:
Functional
earth
Input
voltage
DALI
0-10V
LED module/external NTC
/ STELARIA
Functional earth
X
Double
Double
Double
Double
Input voltage
Double
X
Main
Main
Double
DALI
Double
Main
X
Main
Double
0-10V
Double
Main
Main
X
Double
LED module/external NTC / STELARIA
Double
Double
Double
Double
X
NOTE:
When the devices are built into luminaires, the cabling between the different components must observe the insulation class for
which these lighting fixtures have been designed, as well as comply with the EN 60598 standard.