3 Technical Data
Page 6
3. Technical Data
Oil-Fired Warm Air Heaters
Model
P 40
P 60
P 80
P 100
P 120
Output
kcal/h
kW
BTU
34000
40
136500
51000
60
204700
69000
80
273000
86000
100
341200
103000
120
409450
Fuel consumption
l/h
Kg/h
4
3,1
6
4,7
8
6,2
10
7,8
12
9,4
Air output
m
3
/h
cfm.
4400
2596
6200
3658
7700
4543
7700
4543
7700
4543
Motor speed
rpm
1400
1400
1400
1400
1400
Electric Tension 50-60Hz
V
50Hz
V
230
400
230
400
230
400
230
400
230
400
Electric current
230V-50Hz A
400V-50Hz A
2,2
1,2
2,5
1,3
3,5
1,5
3,5
1,5
3,7
1,6
Power
230V-50Hz W
400V-50Hz W
480
450
550
490
770
570
770
570
810
600
Sound pressure
dBA
67
70
73
73
76
Weight
Kg
48
51
55
55
65
Throw ventilator
m
30
30
40
40
50
Length
mm
1288
1288
1288
1288
1288
Height
mm
455
515
550
550
550
Width
mm
521
576
624
624
624
Diameter mantle
mm
425
475
520
520
520
Distance centre brackets
mm
800
800
800
800
800
The P 40 - P 120 consists of
4 main components
:
1. Shell
: used for air supply.
2. Combustion chamber
: the oil/air mixture is burned in the chamber and ignited by spark ignition.
3. Ventilator
: this conveys the hot air into the room, supplies the air needed for
combustion and the air for cooling the combustion chamber and the flue
gases.
4. BCU
: the Burner Control Unit; the regulation and safety apparatus.
Description of materials:
Shell and burner chamber
: High-grade 430 stainless steel
BCU
: PPE
The materials used are capable of withstanding the maximum loads.