Checking the usage

Communications module ACM WAVE 

SYSTEM RF for gas meters with Absolute 

ENCODER AE2

ACM WAVE SYSTEM RF for recording and forwarding 

absolute meter readings.

The “V-Drive” option allows additional activation and 

status messaging of the valve incorporated in the gas 
meter. The valve is designed for the remote connec-
tion and disconnection of the gas supply.

The ACM WAVE SYSTEM RF comprises the TRANS-

MITTER and the RECEIVER. The TRANSMITTER is 
directly connected to the index. The RECEIVER is 
connected to the receiving unit.

As an option for supporting the wireless link, a 

 REPEATER can be additionally connected.

This function is only guaranteed when used within the 

specified limits – see page 6 (Technical data). Any 
other use is considered as non-compliant.

Type code

Code

Description

ACM

Absolute ENCODER 

communications module

WAVE SYSTEM RF

Radio system

V-Drive

Smart valve control

Part designations

2

1

6

3

5

7

4

1

  Gas meter

2

  Absolute ENCODER AE2

  ACM WAVE TRANSMITTER RF

4

  ACM WAVE RECEIVER RF with base plate

5

  ACM WAVE REPEATER RF with base plate

6

  Retaining screw

7

  Calibration seal

Installation

Attaching the RECEIVER base plate

 

The RECEIVER RF/REPEATER RF base plate 

offers a wide range of mounting options.

 

To attach, excepting the oblong holes 

 A 

, the 

open upper housing must be removed from the 
base plate.

A

A

C

D

E

E

D

C

C

C

B

B

3

4

1

2

Fitting the base plate to a wall

 

Use oblong holes 

 A 

 or 

 B 

 for 3 mm diameter 

screws.

Fitting the base plate to a DIN rail

 

Use 

 C 

 to snap onto a DIN rail.

Fitting the base plate to a pipe

 

For attaching to a vertical pipe with cable ties, 
use holes 

 D 

, and for attaching to a horizontal 

pipe, use holes 

 E 

.

 5 

 Push the upper housing back onto the base 

plate.

Summary of Contents for ACM WAVE SYSTEM RF

Page 1: ...ediately Storage Store the product in a dry place Ambient tempera ture see Technical data Disposal Components particularly batteries are to be dis posed of separately On request old units may be returned carriage paid to Elster GmbH in accordance with the relevant waste legislation requirements for Germany KrW AbfG Act for Promoting Closed Substance Cycle Waste Management and Ensuring Environmenta...

Page 2: ...sidered as non compliant Type code Code Description ACM Absolute ENCODER communications module WAVE SYSTEM RF Radio system V Drive Smart valve control Part designations 2 1 6 3 5 7 4 1 Gas meter 2 Absolute ENCODER AE2 3 ACM WAVE TRANSMITTER RF 4 ACM WAVE RECEIVER RF with base plate 5 ACM WAVE REPEATER RF with base plate 6 Retaining screw 7 Calibration seal Installation Attaching the RECEIVER base ...

Page 3: ...in During this time there is no communication with the other units of the ACM WAVE SYSTEM At the end of the charging time the green LED on the RECEIVER blinks every 10 s and the red LED blinks at a rate of 1 Hertz The charging time can be used for further in stallation work see page 3 Closing and sealing the RECEIVER and 3 Installing the gas meter Closing and sealing the RECEIVER Secure the RECEIV...

Page 4: ...e units have found each other The green LEDs do not blink simultaneously See page 5 Assistance in the event of mal function 3 Confirm that both units have been synchronized To do this hold the permanent magnet on the LEDs on the REPEATER for approx 10 s The green LEDs on the REPEATER and the RECEIVER no longer blink simultaneously The red LED on the REPEATER now blinks at a rate of 1 Hertz The REP...

Page 5: ...eck the connection cable see page 2 The green LEDs on the REPEATER and the RECEIVER do not blink simultaneously The REPEATER has found a foreign RECEIVER e g in a neighbouring room Hold the REPEATER closer to the RECEIVER If the REPEATER is too far away from the RECEIVER the green LED goes out The wireless link is too large To support the wireless link use an additional REPEATER Position the first...

Page 6: ...R RF 5 min ACM WAVE TRANSMITTER RF ACM WAVE REPEATER RF Battery power supply battery service life 15 years The TRANSMITTER is designed for max 4 control commands per hour Smart valve Diaphragm meter BK G4 Ambient temperature 10 to 40 C Opening time from closed to open released state 4 s closing time 0 5 s Min inlet pressure 17 5 mbar Allowed leakage flow in the customers piping valve released max ...

Reviews: