GB-2
D
GB
F
NL
I
E
Checking the usage
Communications module ACM WAVE
SYSTEM RF for gas meters with Absolute
ENCODER AE2
ACM WAVE SYSTEM RF for recording and forwarding
absolute meter readings.
The “V-Drive” option allows additional activation and
status messaging of the valve incorporated in the gas
meter. The valve is designed for the remote connec-
tion and disconnection of the gas supply.
The ACM WAVE SYSTEM RF comprises the TRANS-
MITTER and the RECEIVER. The TRANSMITTER is
directly connected to the index. The RECEIVER is
connected to the receiving unit.
As an option for supporting the wireless link, a
REPEATER can be additionally connected.
This function is only guaranteed when used within the
specified limits – see page 6 (Technical data). Any
other use is considered as non-compliant.
Type code
Code
Description
ACM
Absolute ENCODER
communications module
WAVE SYSTEM RF
Radio system
V-Drive
Smart valve control
Part designations
2
1
6
3
5
7
4
1
Gas meter
2
Absolute ENCODER AE2
ACM WAVE TRANSMITTER RF
4
ACM WAVE RECEIVER RF with base plate
5
ACM WAVE REPEATER RF with base plate
6
Retaining screw
7
Calibration seal
Installation
Attaching the RECEIVER base plate
▷
The RECEIVER RF/REPEATER RF base plate
offers a wide range of mounting options.
▷
To attach, excepting the oblong holes
A
, the
open upper housing must be removed from the
base plate.
A
A
C
D
E
E
D
C
C
C
B
B
3
4
1
2
Fitting the base plate to a wall
▷
Use oblong holes
A
or
B
for 3 mm diameter
screws.
Fitting the base plate to a DIN rail
▷
Use
C
to snap onto a DIN rail.
Fitting the base plate to a pipe
▷
For attaching to a vertical pipe with cable ties,
use holes
D
, and for attaching to a horizontal
pipe, use holes
E
.
5
Push the upper housing back onto the base
plate.