2.3. Notes on mounting and commissioning

Device must not be exposed to water (rain). This could result in the electronic being
damaged. A relative air humidity of 95% must not be exceeded. Avoid bedewing.

3.

Operation

3.1. Central operation

The central input of the 

MSG1-UP

 allows e. g. an automatic control unit, a timer or

even a normal unlocked twin push button (Up/Down) to be connected. The central
command (continuous voltage) always has priority over a movement command from
the manual input. 

If there are "Up" and "Down" movement commands at the central input at the same
time, the drive moves up (secure position).

The central control unit can be set to the operating modes "Lock" (default) or "Dead
man". By simultaneously pressing the 

Up

 and 

Down

 buttons at the manual input, you

can switch between the operation modes:

1. Press the buttons 

Manual-Up

 and 

Down

 simultaneously for 5 seconds,

in order to set the device to readiness for change. 

OR

Switch the mains voltage briefly off and on again. 
After the mains voltage is connected, the device is also in a state of readiness for 
change.

2. The device is now ready for change and it indicates the currently active mode via 

the mode-LED.

   Central command

   Button

     Button

   Manual command

     Manual