background image

3

Installation and commissioning

RF-Router-N

 • Version: 10.05.2016 • Technical changes and errors excepted.

2.

Installation and commissioning

2.1. Installation notes

DANGER!

Risk to life from live voltage (mains voltage)! 

There are unprotected live components within the device.

VDE regulations and national regulations are to be followed.

Ensure that all lines to be assembled are free of voltage and take

precautions against accidental switching on.

Do not use the device if it is damaged. 

Take the device or system out of service and secure it against

unintentional use, if it can be assumed, that risk-free operation is no

longer guaranteed.

The device is only to be used for its intended purpose. Any improper modification or 
failure to follow the operating instructions voids any and all warranty and guarantee 
claims.

After unpacking the device, check it immediately for possible mechanical damage. If it 
has been damaged in transport, inform the supplier immediately.

The device may only be used as a fixed-site installation; that means only when assem-
bled and after conclusion of all installation and operational start-up tasks and only in 
the surroundings designated for it.

Elsner Elektronik is not liable for any changes in norms and standards which may occur 
after publication of these operating instructions.

2.2. Notes on wireless equipment

When planning facilities with devices that communicate via radio, adequate radio re-
ception must be guaranteed.  The range of wireless control will be limited by legal reg-
ulation and structural circumstances. Avoid sources of interference and obstacles be-
tween receiver and transmitter, that could disturb the wireless communication. Those 
would be for example:

Walls and ceilings (especially concrete and solar protection glazing).

Metal surfaces next to the wireless participants (e. g. aluminium construction 
of a conservatory).

Other wireless devices and powerful local transmitters (e.g. wireless 
headphones), which transmit on the same frequency (868,2 MHz). Please 
maintain a minimum distance of 30 cm between wireless transmitters for that 
reason.

Summary of Contents for RF-Router-N

Page 1: ...tructions Part number 60529 Elsner Elektronik GmbH Control and Automation Technology Sohlengrund 16 D 75395 Ostelsheim Phone 49 0 70 33 30 945 0 info elsner elektronik de Germany Fax 49 0 70 33 30 945 20 www elsner elektronik de EN Technical Service 49 0 70 33 30 945 250 ...

Page 2: ...ury caused by components moved automatically If the wireless connection between the control unit and the wireless actuator is interrupted connected devices can no longer be operated For that reason do not connect drives to the wireless actuator which could be hazardous to human life 1 1 Technical specifications The product is compliant with the provisions of EU guidelines 1 2 Deliverables Router i...

Page 3: ...supplier immediately The device may only be used as a fixed site installation that means only when assem bled and after conclusion of all installation and operational start up tasks and only in the surroundings designated for it Elsner Elektronik is not liable for any changes in norms and standards which may occur after publication of these operating instructions 2 2 Notes on wireless equipment Wh...

Page 4: ...uted through the RF Router N if the transmission path is too long for a direct connection 2 3 1 Radio communication schema Radio actuators ventilators relays motor control units can only be operated with the remote control Remo 8 via the controller They can not be additionally switched di rectly with the remote control 2 4 Notes on mounting and commissioning Device must not be exposed to water rai...

Page 5: ...rately before installation 1 Put the control unit into teaching mode observe the corresponding manual data sheet 2 Plug in the RF router The device learns a connection to the control unit on its own 3 seconds after the mains voltage is applied Only one radio client can be recog nised at a time Observe the response from the control system device taught The procedure for assigning radio clients to t...

Reviews: