Radio dimmer RF-L UN-ST IP53 and RF-L LED-ST IP53
2
Radio dimmer RF-L UN-ST IP53 and RF-L LED-ST IP53
from software version 5.7 • Version: 16.05.2022 • Technical changes and errors excepted. • Elsner Elektronik GmbH • Sohlengrund 16 • 75395 Ostelsheim • Germany • www.elsner-elektronik.de •
Technical Service: +49 (0) 7033 / 30945-250
2.2.1. Connection assignment
2.3. Establish wireless connection
1. Set the control unit and/or remote control or the button to teaching mode (obser-
ve the corresponding manual/data sheet)
2. Switch on the
RF-L UN-ST IP53 und RF-L LED-ST IP53
voltage supply or shut
it off for at least 3 seconds if the unit is already supplied with power.
3. For 5 minutes after connecting the voltage, the
RF-L UN-ST IP53 und RF-L
LED-ST IP53
will send a "Learn" telegram every 10 seconds.
4. The wireless connection will be established automatically. For building control
systems, the display will display "Device is learning".
5. The
RF-L UN-ST IP53 und RF-L LED-ST IP53
will stop sending "Learn" tele-
grams once the reply "Learned" (for a learning process) or a control command is
received (in the event of a power interruption during operation).
2.4. Notes on mounting and commissioning
Device must not be exposed to water (rain). This could result in the electronics being
damaged. A relative air humidity of 95% must not be exceeded. Avoid condensati-
on.
3.
Disposal
After use, the device must be disposed of in accordance with the legal regulations.
Do not dispose of it with the household waste!
1 Neutral conductor
2 L
3 nc*
PE
1 Neutral conductor
2 Lamp
3 nc*
PE
* not connected
PE
PE
Input power supply
Plug for STAK3 coupling
Output Lamp
Coupling for