Display and operation at the device

Sensor KNX AQS/TH-B-UP

 • as of software 3.1 • Status: 24.09.2014 • Technical changes reserved. Errors reserved.

3.

Display and operation at the device

Specifications for the display are set in the ETS and the use of the push buttons is
permitted or disabled. 

Basically the display can show a two-row or three-row text (e. g. for measured values)
or a tempertuare controller. You can switch between the two types by pressing one of
the buttons, if this has not been disabled in the ETS.

3.1. Mode display and manual temperature 

controller

Depending on the ETS setting selected, the mode display will only display show the
current target value, or the base target value setting with scale display. The manually
adjustable range can be set in the ETS.

The following display options are available:

Fig. 4

Mode display with current target value and/or base
target value

Fig. 5

Mode display with scale display for adjusting the base
target value. 
The control position in the image reads "Base target
value reduced".

Fig. 6

Mode display with scale display and number. 
Shows the set target value change. 
The control position in the image reads "Base target
value reduced to 1.0°".

Fig. 7

Mode display with scale display and range. 
Shows the possible adjustment range (as set in the ETS). 
The control position in the image reads "Base target
value reduced".

Summary of Contents for KNX AQS/TH-B-UP

Page 1: ...0 aluminium 70241 anthracite 70242 stainless steel EN Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone 49 0 70 56 93 97 0 info elsner elektronik de Germany F...

Page 2: ...rom the bus e g date time The housing is completed with a frame of the switching series installed in the building and thus merges with the interior Functions Measurement of CO2 concentration of the ai...

Page 3: ...ble for the switching programme used in the building 1 1 Technical specifications Housing Plastic material partly lacquered Colours White glossy similar to RAL 9016 Traffic White Aluminium matt Anthra...

Page 4: ...of the bus voltage if the sensor has been in contact with fresh air 350 450 ppm at least once in this period After this the CO2 sensor will recalibrate every two weeks by defining the lowest measured...

Page 5: ...follow the operating instructions voids any and all warranty and guarantee claims After unpacking the device check it immediately for possible mechanical damage If it has been damaged in transport in...

Page 6: ...ing or cooling of the building structure on which the sensor is mounted e g due to sunlight heating or cold water pipes Connection lines and ducts which lead from warmer or colder areas to the sensor...

Page 7: ...to the metal frame so that sensor and frame are fixed 2 5 Notes on mounting and commissioning Never expose the device to water e g rain or dust This can damage the electronics You must not exceed a re...

Page 8: ...he ETS setting selected the mode display will only display show the current target value or the base target value setting with scale display The manually adjustable range can be set in the ETS The fol...

Page 9: ...ressed for Priority 1 operating modes The individual operating modes can also be locked for manual selection in the ETS Comfort mode Comfort present target temperature will be used Standby mode Standb...

Page 10: ...Ambient temperature in the current mode is increased The sep size is defined in the ETS 0 1 C to 5 C Change mode press left or right button longer than 2 secs Changes between the operating modes Comfo...

Reviews: