23
7. Saving of basic settings
At the end of basic settings, the symbol
(save) asks whether the
accomplished setting shall be saved.
Press the
key in order to save your entered data and to access the
meteorological data display. With , you quit the basic settings without saving.
After the basic setting, the values for the automatic functions may be set. In case
of first commissioning, please check the function of the sensors in advance (see
chapter “Sensor testing").
Safety instructions
for automatic and alarm functions
In case of power fail at the weather station, the control system cannot actuate
the connected drive mechanisms anymore! If the complete scope of functions
must be guaranteed in case of power fail, an emergency power generator with
an according switch-over from mains operation to emergency operation must be
installed.
Saved settings in the programme of the control also retain in case of power fail.
After the return of voltage, the control is in automatic mode.
If the radio connection between operating unit and weather station is interrupted
(e.g. by radio interference or empty batteries in the operation unit), it is not
possible anymore to take manual action. The control remains in the current
mode (manual or automatic). The automatic mode continues as preset until
there is radio connection again, however without considering the indoor
temperature. In case of a preset manual mode, the wind and rain protection
functions are retained as well.