background image

iNode Control ID – instruction manual

ELSAT s.c.

At the top of the window there is displayed following information:

the name of the 

iNode

 family – in this case 

iNode Control ID;

the unique device identifier;

battery level: 100% means 3V or greater, while 0% it is 1,8V;

signal strength received by this device from the BT4.0 adapter or iNode LAN;

temperature;

At the 

Bluetooth

 tab there are following items: 

Name

: you can change default device name typing a new one in this text box. Its length is 16

characters maximum.

Tx power

: determine the power the device broadcasts and simultaneously the range the device

can be scanned. If 

iNode Control Point

 has set the scan range 

~200m

, and 

iNode Control ID

has set the broadcast power 

-2dBm range 33%

 then effective distance from which the device can

be scanned is equal 

200m*0,33=66m

.

UUID ident:  

necessary for some applications or different iNode devices e.g. iNode Control

Point. Its length is 16 characters maximum.

Advertising

: you can chose the channels the 

iNode Control ID 

broadcasts advertising frames.

This way the battery life can be extended but device can be more difficult to scan. Additionally
the advertisement interval can be chosen. This time determine how fast you can connect with the
device.

You can save modified settings by pressing the 

Write

 button.

page 4

Summary of Contents for iNode Control ID

Page 1: ...iNode Control ID Instruction manual 2014 2016 ELSAT...

Page 2: ...elp to control the movement of people or goods saving the time of appearance and disappearance active RFID long range New features related to the development of the product is also not a problem this...

Page 3: ...CSR iNode Serial Transceiver signed COM or iNode LAN signed the name of the device In case the application cannot start or system error you should try to install Microsoft Visual C 2005 Service Pack...

Page 4: ...adcasts and simultaneously the range the device can be scanned If iNode Control Point has set the scan range 200m and iNode Control ID has set the broadcast power 2dBm range 33 then effective distance...

Page 5: ...ection by battery removing for at least one minute This type of protection cannot be set in case of iNode Control Point Connection is password protected access to the iNode Control ID is password prot...

Page 6: ...tton erases the archived data memory and at the same time enabling archiving data Data in memory are saved in a cyclical buffer eg after it is full the oldest data will be erased Memory has a capacity...

Page 7: ...e Firmware is uploaded to the device after clicking Send firmware button Application checks if this firmware is correct for this type of device to avoid situation that we want to upload the firmware w...

Page 8: ...with the metal battery holder 2 Remove the circuit board from the enclosure The battery is inserted into the holder on the side It can not be removed if the plate is located in the housing 3 Pull out...

Page 9: ...ts against its copying and use by another client Power supply the battery CR2032 Housing plastic dimensions 32 mm x 9 5 mm Other remote firmware update counterfactual firmware iNode Care Sensor 1 two...

Page 10: ...and it over to an electric and electronic device collection and recycling point The crossed out wheelie bin symbol placed on the product instruction manual or package communicates this requirement Pla...

Page 11: ...9 2 2012 PN ETSI EN 301 489 3 V1 6 1 2014 03 PN ETSI EN 301 489 17 V2 2 1 2013 05 PN ETSI EN 300 328 V1 8 1 2013 03 PN EN 62479 2011 Ap1 2013 07 The product herewith complies with the requirements of...

Reviews: