- 2 -
Thank you for purchasing our smoke alarm!
Please read these instructions carefully and store them in a safe place where you can access them
easily.
Product description and intended use
This is a smoke alarm with radio link function with an optical sensor for installation in residential
buildings, apartments and rooms with residential-like use. Smoke alarms are designed to provide an
early warning of fire smoke and fires to persons present, so that these persons can react
appropriately to the hazardous event. Always consult local regulations for smoke alarms.
Product specifications
Detection method
: Optical
Power supply
: Sealed battery 3V DC
Battery lifetime
: 10 years
Alarm volume
:
≥ 85 dB (A) at 3 meters
Monitored area
: 40 m²
Operating temperature
: 0 °C - 45 °C
Operating humidity
: < 93 %
Date of replacement
: See product label
Individual alarm indicator
: Yes
Alarm silence facility
: Yes | Hush time: 5-15 minutes
Low battery warning
: Yes
Low battery silence facility
: Yes | Hush time: 10 hours
Installation in leisure accommodation vehicles : Yes
Mounting location
: Ceiling or wall
Interconnectable
: Yes | max. 40 devices
Wireless frequency
: 868.3 MHz
Wireless distance
: 35 meters (100 meters open space)
Warnings
•
To prevent injury, this apparatus must be securely attached to the ceiling/wall in accordance with
the installation instructions.
•
Batteries should not be exposed to excessive heat such as sunshine, fire or the like.
•
Do not paint or cover the smoke alarm.
Where to install a smoke alarm
•
Smoke alarms must be installed in such a way that they can be reached unhindered by the fire
smoke so that fires can be reliably detected during the development phase.
•
Install at least in sleeping areas (especially children's rooms).
•
Install at least in escape rooms.
•
In the middle of the ceiling of a room.
•
At least 50 cm away from the wall and other objects.
•
Maximum installation height of 6 meter.
•
If ceiling installation is not possible, the smoke alarm can be installed on the wall. The distance to
the ceiling should be between 30 and 50 centimeters.