Technical Manual MiniMEP Data Loggers

page 7

- The terminals 10 and 11are valid

only for MiniMEP's with option 'A'

- Terminals 3 to 8 not available in

type 404 S

Wiring MiniMEP (2)404S, (2)424A

MiniMEP

P

ELREHA

Wiring the probes / sensors

1  2  3  4  5  6  7  8  9

11  13  15  17  19  21  23  25

10  12  14  16  18  20  22  24

Wiring MiniMEP 424/12V

11  13  15  17  19  21  23  25

10  12  14  16  18  20  22  24

10 Accu +

11 Accu -

12 RS 485 NDO

13 RS 485 DO

14 Probe 1

15 Probe 1 com.

16 Probe 2

17 Probe 2 com.

18 Probe 3

19 Probe 3 com.

20 Probe 4

21 Probe 4 com.

22 n.c.

23 RxD (RS 232)

24 GND (RS 232)

25 TxD (RS 232)

M

a

in

p

h

a

se

 2

3

0

V

 (

U

S

=

1

1

5

V

)

L

/r

e

p

o

rt

 in

p

u

1

 (

a

l1

m

a

in

p

h

.

L

/r

e

p

o

rt

 in

p

u

3

 (

d

o

o

r)

 m

a

in

p

h

.

L

/r

e

p

o

rt

 in

p

u

2

 (

a

l2

m

a

in

p

h

.

a

la

rm

 r

e

la

N

/O

 c

o

n

ta

ct

M

a

in

n

e

u

tr

a

l

a

lr

m

 r

e

la

N

/C

 c

o

n

ta

ct

a

la

rm

 r

e

la

co

m

m

o

n

P

E

1  2  3  4  5  6  7  8  9

RS-232 Interface MiniMEP 4xx

RS-232-interface connector

These ports are also connected to the screw
terminals 23-25.
They may not be connected at the same time

connector SUB-D 9 male

2

6

1

3

5

7

9

8

4

TxD (data out)

GND

RxD (data in)

MiniMEP

P

ELREHA

10  12  14  16  18  20  22  24

a

la

rm

 r

e

la

N

/O

 c

o

n

ta

ct

a

la

rm

 r

e

la

N

/C

 c

o

n

ta

ct

re

p

o

rt

 in

p

u

1

 (

a

l1

+

1

2

V

 D

C

re

p

o

rt

 in

p

u

2

 (

a

l2

+

1

2

V

 D

C

re

p

o

rt

 in

p

u

3

 (

d

o

o

r)

 +

1

2

V

 D

C

S

u

p

p

ly

 v

o

lta

g

e

 +

1

2

V

 D

C

S

u

p

p

ly

 v

o

lta

g

e

 -

1

2

V

 D

C

a

la

rm

 r

e

la

co

m

m

o

n

1  2  3  4  5  6  7  8  9

10 n.c.

11 n.c.

12 RS 485 NDO

13 RS 485 DO

14 Probe 1

15 Probe 1 com.

16 Probe 2

17 Probe 2 com.

18 Probe 3

19 Probe 3 com.

20 Probe 4

21 Probe 4 com.

22 n.c.

23 RxD (RS 232)

24 GND (RS 232)

25 TxD (RS 232)

11  13  15  17  19  21  23  25

Summary of Contents for MiniMEP 2404S

Page 1: ...minute interval Example 2 6 years with a 15 min interval z Data storage is unlimited even without mains voltage z Real time clock with typ 10 years battery backup z Continuous recording by external le...

Page 2: ...4A 534A canrecord2temperature values and the values of two 4 20 mA humidity transmitters Type Housing Inputs Recording Digital Alarm Limits LC Input for Memory Cap Supply Overview Range inputs Alarm r...

Page 3: ...01 07 96 14 15 sensor 2 21 0 C 01 07 96 14 30 01 07 96 14 45 01 07 96 15 00 P P MINIMEP serial no 000000 01 07 96 14 30 01 07 96 15 00 01 07 96 14 45 correction probe selection push for longer than 1...

Page 4: ...abled during accu operation Real time clock The integrated x tal controlled real time clock can be corrected by only 24 hours Theautomaticsummer winter shiftcanbedisabledforexportpurposes Without main...

Page 5: ...delay is run down an alarm message will be generated 0 01 4 00 h min 1 00 h min name transm 3 individual name for this probe input max 8 characters see table transmitter 3 probe 4 corr 1 the last fou...

Page 6: ...l be generated 0 01 4 00 h min 1 00 h min name probe 3 individual name for this probe input max 8 characters see table probe 3 probe 4 corr 1 the last four corrections of this input with time to date...

Page 7: ...mains ph L report input 2 al2 mains ph alarm relay N O contact Mains neutral alrm relay N C contact alarm relay common PE 1 2 3 4 5 6 7 8 9 RS 232 Interface MiniMEP 4xx RS 232 interface connector The...

Page 8: ...14 input 1 4 20mA 15 input 1 4 20mA 16 probe 2 17 probe 2 com 18 input 3 4 20mA 19 input 3 4 20mA 20 probe 4 21 probe 4 com 22 n c 23 RxD RS 232 24 GND RS 232 25 TxD RS 232 51 R 51 R 11 13 15 17 19 21...

Page 9: ...t A don t need the cables between terminals 37 and 38 TxD data out RxD data in 1 4 2 3 5 Stecker SUB D 9 polig male 7 6 9 8 GND 31 32 16 17 to controller unit PE Mains N Mains Line L Input 1 L Input 2...

Page 10: ...16 17 18 19 ELREHA 63 47 34 35 36 37 38 34 35 36 37 38 93 105 L Eing 1 NK L Eing 2 TK L Ein 3 T r Dimensions of MiniMEP 4xx types Dimensions Terminals of MiniMEP 2 524 A 2 534 A Operating Unit Verbin...

Page 11: ...ler an unlock code must be entered while start up You get this unlock code with the software please see software manual for further information Without this code retrieve and processing of data with t...

Page 12: ...y please contact the manufacturer first Electrical installation and putting into service must be done from authorized personnel Please note the local safety instructions Before installation Check the...

Page 13: ...m relay SPDT isolated 4A cos phi 1 250V Interfaces RS 232 RS 485 Accu interface Chargecontrollerfor1 3AhLeadAccus not types 404 S 2404 S 424 12V Data memory see type overview Real time clock automatic...

Page 14: ...heir companies copy We state the following When operated in accordance with the technical manual the criteria have been met that are outlined in the guidelines of the council for alignment of statutor...

Page 15: ...Drilling template MiniMEP x422 x424 Ma stab 1 1 scale 1 1 116mm 4 57 Bohrer Drill 6mm 24 7mm 27 Bohrer Drill 6mm 24 11 43 163 5 6 42 155 6 1 65mm 2 56...

Reviews: