Betriebsanleitung/

Manual

 EGS AE

Abmessungen /

 Dimensions

We state the following: When operated in accordance with the technical manual, the criteria have been met that are outlined in the EMC Directive 

2004/108/EC

 and the Low Voltage Directive 

2006/95/EC

Following standards were consulted for the conformity testing to meet the requirements of EMC and Low Voltage Guidelines:

 

EN 55011:2009+A1:2010, EN 61010-1:2010, EN 61326-1:2013 

 

CE marking of year: 2015

This statement is made for the manufacturer / importer 

by: 

ELREHA Elektronische Regelungen GmbH 

Werner Roemer, 

Technical Director 

D-68766 Hockenheim 

 

 

 

 

 

 

www.elreha.de   

Hockenheim

.............

10.12.2015

.......................................................

(

Name / Address

C

ity 

Date

 

 

S

ignature

EC Declaration of Conformity

Diese Anleitung haben wir mit größter Sorgfalt erstellt, Fehler können wir aber nie ganz ausschließen. Unsere Produkte sind einer ständigen Pflege unterworfen, 

Änderungen der Konstruktion sind also möglich und vorbehalten. Sollten Sie Probleme haben, sprechen Sie uns bitte an.

Hinweis

Die  Länge  der  Verbindungskabel  zum 

Sensormodul sollten nicht 50m (0,5mm

WG21)  bzw.  35m  (0,34mm

2

/A  WG22) 

überschreiten.  Abgeschirmte,  geerdete 

Leitungen sind wichtig.

Bitte Sicherheitshinweise vor dem 

Anschluss lesen!

Technische Daten

Betriebsspannung .........................................230V AC, +10/-15%, 50 Hz

Leistungsaufnahme ...............................................................max. 8,0 VA

Betriebstemperatur ................................................................ -30...+50°C

Lagertemperatur .................................................................... -30...+60°C

Umgebungsfeuchte ...........................max. 80% r.F. nicht kondensierend

Relaisausgänge ..............2x Wechsler pot.frei, 8A res./ 3A ind., 230V AC

Akustischer Alarm ........................................................................ > 88 dB

Sensoreingang ...................................................4...20 mA, Ri=100 Ohm

Spannungsversorgung Sensor ............................. 22V DC, max. 150 mA

Sensorsignal .....< 4mA Fehlermeldung, 4 mA/0 ppm, 20 mA/50000 ppm

Ausgang externer Warnsummer (buzzer) ........................Open Collector

Spannungsversorgung Warnsummer (buzzer) ....... 12V DC, max. 20 mA

Elektrischer Anschluss................................... Schraubklemmen, 2,5mm²

Alarmschwellen  .................................Stufe 1: einstellbar (siehe Seite 2)

(Werkseinstellung) 

Stufe 2: einstellbar (siehe Seite 2)

Normbezug ............................................................................... EN-378-1 

Gehäuse/Schutzart  ............................................... Wandmontage / IP 54 

Technical Data

Supply Voltage .............................................230 V AC, +10/-15%, 50 Hz

Power Consumption ............................................................. max. 8,0 VA

Operating Temperature ......................................................... -30...+50°C

Storage Temperature ............................................................. -30...+60°C

Ambient Humidity .....................................max. 80% r.H. not condensing 

Relay Outputs ..................... 2x SPDT-contact, 8A res./ 3A ind., 230V AC 

Acoustic Alarm by the Internal Buzzer ......................................... > 88 dB

Sensor Input ................................................4...20 mA, Burden 100 Ohm

Power Supply Sensor ...........................................22V DC, max. 150 mA 

Sensor Signal .... < 4mA Fail. Message, 4 mA/0 ppm, 20 mA/50000 ppm

Output external Buzzer .....................................................Open Collector

Power Supply Buzzer .............................................12V DC, max. 20 mA

Electrical Connection ........................................ screw terminals, 2,5mm²

Threshold Values ....................................... Limit 1: settable (see page 2)

(factory settings) .............................................. Limit 2: settable (see page 2)

Supports you for standard ........................................................ EN-378-1 

Housing / Protection  ..............................................Wall mounting / IP 54

Wires connected to sensor unit interface 

shall not exceed 50m in lenght for 0,5mm

WG21  respectively  35m  for  0,34mm

2

/A 

WG22. Shielded wires with shield connec-

ted to earth are highly recommended.
Please always read Safety Information and 

Mounting Instructions before use! 

Ideale Wandmontage:

Deckel öffnen und an allen 

4 Ecken passenden 

Schrauben einführen.

Ideal wall mounting:

Open cover and insert 

screws at all 4 corners.