Remote Control Programming User’s Guide
PM024A02 Rev.2
28
4.1 Multi-FPA instructions
The Multi-FPA API-DLL instructions are related to Multi-FPA selector only. These
instructions allows to initialize all single applications dlls and select the instruction patch
between application software and desired FPA and sequential/simultaneous instructions transfer
management Up to eight independent FPAs can be remotely controlled from the application
software. All instructions from application software can be transferred to one selected FPA or to
all FPAs at once. That feature allows to increase programming speed up to eight times and also
allows to have individual access to any FPA is required.
F_Trace_ON
F_Trace_ON
- This function activate the tracing.
Syntax:
void MSPPRG_API
F_Trace_ON( void );
The F_Trace_ON() opens the DLLtrace.txt file located in the current directory and records all
API-DLL instructions called from the application software. This feature is useful for debugging.
When debugging is not required then tracing should be disabled. Communication history
recorded in the in the last session can be viewed in the DLLtrace.txt located in the directory
where the API-DLL file is located. When the new session is established then the file
DLLtrace.txt is erased and new trace history is recorded.
Note:
Tracing is slowing the time execution, because all information passed from application
software to API-DLL are recorded in the dlltrace.txt file.
F_Trace_OFF
F_Trace_OFF
- Disable tracing, See
F_Trace_ON
for details.
Syntax:
void MSPPRG_API
F_Trace_OFF( void );
F_OpenInstances
Summary of Contents for FlashPro-CC