background image

Operating Instructions No. 9999-043-0

Seite 4

B7215e01_2.pmd

Rel. 1 vom 10.09.2003

10.1 Programming the master combination

Possible only with the electronic lock open and only by using the master combination.

Function

Operation, button(s)

Response

Initiate programming
Select P No. 0
Confirm the entry
Enter previous 6-digit combination, e.g. °
Confirm the entry
Enter new 6-digit combination, e.g.
Confirm the entry
Enter new combination again to confirm
Confirm the entry

OK = green LED lights and
low-high tone sounds.

Cancel

Error = 12 high-pitched
tones and red LED lights.

Please check to ensure
that the lock functions
correctly with the new
master combination
before closing the safe
door.

°  Set at the factory for
1 - 2 - 3 - 4 - 5 - 6

Comments

Green LED blinks once

Close the lock:
Press any digit button

10.2 Programming a user combination

A user combination can be set up for the first time only by the master combination owner. Changes to a
user combination may be made with either the master combination or the particular user combination.
Programming is possible only with the electronic lock open.

Initiate programming
Select P No. 1
Confirm the entry
Select user number, e.g. °
Confirm the entry
Enter the 6-digit master or user combination, e.g.
Confirm the entry
Enter the new 6-digit user combination, e.g.
Confirm the entry
Enter the new user combination again to confirm
Confirm the entry

Cancel

A maximum of 9 user
combinations can be
programmed

9

8

7

6

5

4

The previous user
combination will be
retained if there is an
error in programming.

  °

= UNo. 1

= UNo. 9

User 9 =Override combination

Green LED blinks once

OK = green LED lights and
low-high tone sounds.
Error = 12 high-pitched
tones and red LED lights.

9

8

7

6

5

4

Close the lock:
Press any digit button

Function

Operation, button(s)

Response

Comments

Initiate programming

Confirm the entry
Select the user combination to be deleted, e.g.2 °
Confirm the entry
Enter the 6-digit master combination e.g.
Confirm the entry
Re-confirm the entry

Cancel

The previous user
combination will be
retained if there is an error
in programming.

If fewer than 3 user combinations
are programmed, then any
combination interlock which may
have been programmed
previously will have to be deleted.
See Section 10.3.2

10.2.1 Deleting a user combination

Only the master combination owner can delete a user combination and only with the electronic lock open.

Green LED blinks once

Close the lock:
Press any digit button

OK = green LED lights and
low-high tone sounds.
Error = 12 high-pitched
tones and red LED lights.

Function

Operation, button(s)

Response

Comments

°       = UNo. 1

= UNo. 9

Summary of Contents for 7215

Page 1: ... A series of digits required to open the lock It comprises the User number and combination e g master combination 0 _ 6 5 4 7 2 1 e g user combination 3 _ 8 7 9 5 8 3 Factory combination The initial combination programmed at the factory For this electronic lock the combination has been pre set to 0 _ 1 2 3 4 5 6 Master combination Combination used by the master to open the lock User combination Co...

Page 2: ...ed with the C button The red LED blinks every five seconds during the time out period The end of the time out period is indicated by the green LED blinking and a single low high signal It is now necessary to enter a valid combination twice in order to open the electronic lock This is done by connecting the new battery 9 volt alkaline to the emergency contacts located at the keypad Important Observ...

Page 3: ...the door If the model 7216 3XX X or 7217 3XX X electronic lock has been opened under motor power then it cannot be closed with the emergency release key 7 1 Closing after emergency release 7216 7217 Rectify the problem Close the emergency release feature enter the master or user combination and then press any digit key 7 2 Closing after emergency release 7216 3XX X 7217 3XX X Close the emergency r...

Page 4: ... the 6 digit master or user combination e g Confirm the entry Enter the new 6 digit user combination e g Confirm the entry Enter the new user combination again to confirm Confirm the entry Cancel A maximum of 9 user combinations can be programmed 9 8 7 6 5 4 The previous user combination will be retained if there is an error in programming UNo 1 UNo 9 User 9 Override combination Green LED blinks o...

Page 5: ...umber see example below Once the first user combination has been entered a beep will sound every five seconds for a period of 60 seconds If the second user combination is not entered within this 60 second period then the entry will be discarded and both user combinations will have to be entered again Example Button for UNo 1 Button for UNo 2 etc through to button for UNo 9 Function Operation butto...

Page 6: ...y digit button 10 4 Programming a timed delay period Possible only with the electronic lock open and only with the master combination It is possible to program a release period in combination to the time delay periode The release periode is set to 1 Minute on factory suply For reprogramming see 10 5 Explanation Timed delay period Period from entering a combination the first time to clearance for e...

Page 7: ...onfirm the entry Enter 6 digit master combination e g Confirm the entry Activating of power safe mode Confirm the entry Cancel Comments Green LED blinks once OK green LED lights and low high tone sounds Error 12 high pitched tones and red LED lights Close the lock Press any digit button Programming I O functions Programming is possible with the electronic lock closed or open and only with the mast...

Page 8: ...d LED lights IMPORTANT After the function is deleted the lock will automatically close one more time after 10 seconds have elapsed Can be programmed only with the electronic lock open and only with the master combination 10 8 Programming an override combination An override combination permitting immediate opening even if a time lock period has been specified can be set up for the first time only b...

Page 9: ...hour to 99 hours Comments Green LED blinks once OK green LED lights and low high tone sounds Error 12 high pitched tones and red LED lights Following the final entry confirmation the electronic lock will respond to no keyboard commands whatsoever during the specified time lock period After the programmed time lock period has elapsed the electronic lock may be opened with the master combination or ...

Page 10: ... can be obtained from CARLWITTKOPP GmbH KG Sternbergstr 5 D 42551 Velbert Germany Phone 49 2051 95660 Fax 49 2051 956666 or INSYS Waffnergasse 8 D 93047 Regensburg Germany Phone 49 941 560061 Fax 49 941 563471 Descriptions of the functions and operating instructions are included with the PC software 14 Reset function This programming option returns all the programmed functions to the factory defau...

Page 11: ...gh pitched tone and the green LED blinks once followed by one low pitched tone and the red LED blinking once Manipulation indicator The keypad has been changed out or invalid combinations were entered three times or the battery has been replaced Enter the combination once again See Section 9 Detecting keypad replacement and tampering Keypad does not respond A timed delay period is running Wait unt...

Page 12: ... improper treatment nor in the event of losses to property or assets due for example to a failure to close the safe properly We recommend obtaining appropriate insurance coverage to protect the contents of your safe Your property insurance sales agent can provide details If the safe cannot be opened even though you have followed the instructions given above then kindly contact the safe manufacture...

Reviews: