Operating Instructions No. 9999-043-0
Seite 1
B7215e01_2.pmd
Rel. 1 vom 10.09.2003
Contents:
1.
Important notes
1.1
Explanation of terms
2.
Opening the electronic lock
3.
Closing the electronic lock
4.
Time-out following erroneous entries
5.
Correction with the ”C“ button
6.
Charge monitoring, replacing the battery
6.1
Opening and closing after replacing the battery
7.
Mechanical emergency release, EloStar 7216 / 7217
and 7216-3XX-X / 7217-3XX-X only
7.1
Closing after emergency release, 7216 / 7217
7.2
Closing after emergency release, and 7216-3XX-X
and 7217-3XX-X
8.
Querying the lock status
9.
Detecting keypad replacement and tampering
10.
Programming the electronic lock
10.1
Programming the master combination
10.2
Programming a user combination
10.2.1 Deleting a user combination
10.3
Activating a combination interlock (duality principle)
10.3.1 Opening the safe with the combination interlock
feature activated
10.3.2 Deactivating the combination interlock function
10.4
Programming a timed delay period
10.4.1 Opening the lock with the timed delay function
activated
10.4.2 Deleting a timed delay period
10.5
Programming a relaese period
10.6
Programming I/O functions (input/output functions)
10.7
Programming for automatic locking
10.7.1 Deleting automatic locking
10.8
Programming an override combination
10.8.1 Deleting an override combination
10.9
Programming a time-lock period
11.
Triggering a silent alarm
12.
Activity logging
13.
Transmitting data from the electronic lock to a PC
14.
Reset function
15.
Troubleshooting
electronic lock
Typ: 7215 / 7216 / 7217/ 7215-3XX-X / 7216-3XX-X / 7217-3XX-X
1.1 Explanation of terms
The following terms and symbols are used:
User number
=
User number (abbreviated
UNo
.)
UNo.
=
0
for master
UNr.
=
1
to
9
for users
Combination
=
A combination (series) of digits,
e.g. 4 7 6 2 3 9
Opening
combination
=
A series of digits required to open
the lock.
It comprises the:
User number and combination
.
e.g. master combination
0 _ 6 5 4 7 2 1
e.g. user combination
3 _ 8 7 9 5 8 3
Factory
combination
=
The initial combination, programmed
at the factory. For this electronic
lock the combination has been pre-
set to
0 _ 1 2 3 4 5 6
.
Master
combination
=
Combination used by the master to
open the lock.
User
combination
=
Combinations for additional users.
All user combinations are
subordinate to the master
combination.
Override
combination
=
Combination which will open the
lock immediately even if a delay
period has been programmed.
P No.
=
Program number
LED
=
Light-emitting diode at the keypad.
Note
=
Caution
=
1. Important notes
•
Beforehand any operation use
C-Button
•
In the interest of security, change the factory
combination
0 _ 1 2 3 4 5 6
immediately.
•
Do not use any personal data for your new master
or user combination.
•
The maximum permissible interval between any two
keypad entries is 60 seconds. If this limit is exceeded,
then the entire procedure will have to be repeated
from the beginning.
•
A signal tone sounds each time a button is pressed.
•
Store the keys used for mechanical emergency
release (only for the EloStar 7216 / 7217 / 7216-3XX-
X / 7217-3XX-X) in a secure place and never inside
the safe itself!
•
A 10-second time-out period will be started after in
valid combinations have been entered in three
consecutive attempts.
•
Do not damage the inspection seal on the lock as
otherwise the guarantee will be invalidated.
Models available
7215
Electronic lock with rigid bolt.
7215-300-0
to
7215-399-0
Electronic lock with spring-loaded bolt.
7216
Electronic lock with rigid bolt and mechanical
emergency release, VdS Class1.
7216-300-0
bis
7216-399-0
Electronic lock with spring-loaded bolt and
mechanical emergency release, VdS Class1.
7217
Electronic lock with rigid bolt and mechanical
emergency release, VdS Class2.
7217-300-0
bis
7217-399-0
Electronic lock with spring-loaded bolt and
mechanical emergency release, VdS Class2.