background image

Operating Instructions No. 9999-043-0

Seite 1

B7215e01_2.pmd

Rel. 1 vom 10.09.2003

Contents:

1.

Important notes

1.1

Explanation of terms

2.

Opening the electronic lock

3.

Closing the electronic lock

4.

Time-out following erroneous entries

5.

Correction with the ”C“ button

6.

Charge monitoring, replacing the battery

6.1

Opening and closing after replacing the battery

7.

Mechanical emergency release, EloStar 7216 / 7217
and 7216-3XX-X / 7217-3XX-X only

7.1

Closing after emergency release, 7216 / 7217

7.2

Closing after emergency release, and 7216-3XX-X
and 7217-3XX-X

8.

Querying the lock status

9.

Detecting keypad replacement and tampering

10.

Programming the electronic lock

10.1

Programming the master combination

10.2

Programming a user combination

10.2.1 Deleting a user combination
10.3

Activating a combination interlock (duality principle)

10.3.1 Opening the safe with the combination interlock

feature activated

10.3.2 Deactivating the combination interlock function
10.4

Programming a timed delay period

10.4.1 Opening the lock with the timed delay function

activated

10.4.2 Deleting a timed delay period
10.5

Programming a relaese period

10.6

Programming I/O functions (input/output functions)

10.7

Programming for automatic locking

10.7.1 Deleting automatic locking
10.8

Programming an override combination

10.8.1 Deleting an override combination
10.9

Programming a time-lock period

11.

Triggering a silent alarm

12.

Activity logging

13.

Transmitting data from the electronic lock to a PC

14.

Reset function

15.

Troubleshooting

electronic lock

Typ: 7215 / 7216 / 7217/ 7215-3XX-X / 7216-3XX-X / 7217-3XX-X

1.1 Explanation of terms

The following terms and symbols are used:

User number

   =

User number (abbreviated 

UNo

.)

UNo.

 = 

0

 for master

UNr.

 = 

to

 9

 for users

Combination

   =

A combination (series) of digits,
e.g.  4 7 6 2 3 9

Opening
combination    

=

A series of digits required to open
the lock.
It comprises the:

User number and combination

.

e.g. master combination
0 _ 6 5 4 7 2 1
e.g. user combination
3 _ 8 7 9 5 8 3

Factory
combination    

=

The initial combination, programmed
at the factory. For this electronic
lock the combination has been pre-
set to

0 _ 1 2 3 4 5 6

.

Master
combination    

=

Combination used by the master to
open the lock.

User
combination

  =

Combinations for additional users.
All user combinations are
subordinate to the master
combination.

Override
combination    

=

Combination which will open the
lock immediately even if a delay
period has been programmed.

P No.

   =

Program  number

LED

   =

Light-emitting diode at the keypad.

Note

=

   Caution

   =

1. Important notes

Beforehand any operation use 

C-Button

In the interest of security, change the factory
combination  

0 _ 1 2 3 4 5 6

  immediately.

Do not use any personal data for your new master
or user combination.

The maximum permissible interval between any two
keypad entries is 60 seconds. If this limit is exceeded,
then the entire procedure will have to be repeated
from the beginning.

A signal tone sounds each time a button is pressed.

Store the keys used for mechanical emergency
release (only for the EloStar 7216 / 7217 / 7216-3XX-
X / 7217-3XX-X) in a secure place and never inside
the safe itself!

A 10-second time-out period will be started after in
valid combinations have been entered in three
consecutive attempts.

Do not damage the inspection seal on the lock as
otherwise the guarantee will be invalidated.

Models available
7215

Electronic lock with rigid bolt.

7215-300-0 

to 

7215-399-0

Electronic lock with spring-loaded bolt.

7216

Electronic lock with rigid bolt and mechanical
emergency release, VdS Class1.

7216-300-0

 bis 

7216-399-0

Electronic lock with spring-loaded bolt and
mechanical emergency release, VdS Class1.

7217

Electronic lock with rigid bolt and mechanical
emergency release, VdS Class2.

7217-300-0

 bis 

7217-399-0

Electronic lock with spring-loaded bolt and
mechanical emergency release, VdS Class2.

Summary of Contents for 7215

Page 1: ... A series of digits required to open the lock It comprises the User number and combination e g master combination 0 _ 6 5 4 7 2 1 e g user combination 3 _ 8 7 9 5 8 3 Factory combination The initial combination programmed at the factory For this electronic lock the combination has been pre set to 0 _ 1 2 3 4 5 6 Master combination Combination used by the master to open the lock User combination Co...

Page 2: ...ed with the C button The red LED blinks every five seconds during the time out period The end of the time out period is indicated by the green LED blinking and a single low high signal It is now necessary to enter a valid combination twice in order to open the electronic lock This is done by connecting the new battery 9 volt alkaline to the emergency contacts located at the keypad Important Observ...

Page 3: ...the door If the model 7216 3XX X or 7217 3XX X electronic lock has been opened under motor power then it cannot be closed with the emergency release key 7 1 Closing after emergency release 7216 7217 Rectify the problem Close the emergency release feature enter the master or user combination and then press any digit key 7 2 Closing after emergency release 7216 3XX X 7217 3XX X Close the emergency r...

Page 4: ... the 6 digit master or user combination e g Confirm the entry Enter the new 6 digit user combination e g Confirm the entry Enter the new user combination again to confirm Confirm the entry Cancel A maximum of 9 user combinations can be programmed 9 8 7 6 5 4 The previous user combination will be retained if there is an error in programming UNo 1 UNo 9 User 9 Override combination Green LED blinks o...

Page 5: ...umber see example below Once the first user combination has been entered a beep will sound every five seconds for a period of 60 seconds If the second user combination is not entered within this 60 second period then the entry will be discarded and both user combinations will have to be entered again Example Button for UNo 1 Button for UNo 2 etc through to button for UNo 9 Function Operation butto...

Page 6: ...y digit button 10 4 Programming a timed delay period Possible only with the electronic lock open and only with the master combination It is possible to program a release period in combination to the time delay periode The release periode is set to 1 Minute on factory suply For reprogramming see 10 5 Explanation Timed delay period Period from entering a combination the first time to clearance for e...

Page 7: ...onfirm the entry Enter 6 digit master combination e g Confirm the entry Activating of power safe mode Confirm the entry Cancel Comments Green LED blinks once OK green LED lights and low high tone sounds Error 12 high pitched tones and red LED lights Close the lock Press any digit button Programming I O functions Programming is possible with the electronic lock closed or open and only with the mast...

Page 8: ...d LED lights IMPORTANT After the function is deleted the lock will automatically close one more time after 10 seconds have elapsed Can be programmed only with the electronic lock open and only with the master combination 10 8 Programming an override combination An override combination permitting immediate opening even if a time lock period has been specified can be set up for the first time only b...

Page 9: ...hour to 99 hours Comments Green LED blinks once OK green LED lights and low high tone sounds Error 12 high pitched tones and red LED lights Following the final entry confirmation the electronic lock will respond to no keyboard commands whatsoever during the specified time lock period After the programmed time lock period has elapsed the electronic lock may be opened with the master combination or ...

Page 10: ... can be obtained from CARLWITTKOPP GmbH KG Sternbergstr 5 D 42551 Velbert Germany Phone 49 2051 95660 Fax 49 2051 956666 or INSYS Waffnergasse 8 D 93047 Regensburg Germany Phone 49 941 560061 Fax 49 941 563471 Descriptions of the functions and operating instructions are included with the PC software 14 Reset function This programming option returns all the programmed functions to the factory defau...

Page 11: ...gh pitched tone and the green LED blinks once followed by one low pitched tone and the red LED blinking once Manipulation indicator The keypad has been changed out or invalid combinations were entered three times or the battery has been replaced Enter the combination once again See Section 9 Detecting keypad replacement and tampering Keypad does not respond A timed delay period is running Wait unt...

Page 12: ... improper treatment nor in the event of losses to property or assets due for example to a failure to close the safe properly We recommend obtaining appropriate insurance coverage to protect the contents of your safe Your property insurance sales agent can provide details If the safe cannot be opened even though you have followed the instructions given above then kindly contact the safe manufacture...

Reviews: