3.1 

In coming water supply quality 

  Check the water quality and water hardness with your local water supply company before  

commencing with the installation. 

  The Incoming water quality should not exceed the following limits. With water it is necessary to know 

about the ingredients and their effects. 

total hardness: 

≤ 3° dH 

pH- value:   

7,0 bis 8,5 

conductivity:  

≤  90 µS/cm 

Cl

-

:   

Max.    60 mg/l 

SO

4

Max.  100 mg/l 

SiO

4

Max.    10 mg/l 

Fe: 

Max. 0,05 mg/l 

Mn: 

Max. 0,05 mg/l 

Cu: 

Max. 0,05 mg/l 

Cl

2

Max. 0,10 mg/l 

Soft water connection: 

  If the total water hardness is ≥ 3° dH at least one hydrogen ion exchanger must be connected upstream 

from the soft water connection on the machine. For our units approved filter systems are partial 

demineralisation filters with integrated particle and activated carbon filtration as well as a bypass. 

  Among others, Brita offers adequate filter systems. 

  Sodium ion exchangers (as normally used for dishwashers) are not permitted for our machines. The 

glass window can become dull and stainless steel components in the cooking chamber could be 

irreparably damaged! 

  Systems with silicate metering must not be used. They can cause malfunctions and scaling in the 

cooking chamber. 

  Systems that operate with electromagnetic fields do not protect against lime scale in this type of machine. 

  If the total water hardness is < 3° dH but the water contains impurities such as sand, iron particles or 

suspended particles, a 5 - 15 µm fine filter must be installed upstream from the soft water connection 

on the machine. 

  If the water is chlorinated Cl

2

 in excess of 0.1 mg/l (corresponding to 0.1 ppm), an activated carbon 

filter must be additionally installed upstream from the soft water connection on the machine. 

Activated carbon filters may also be an integral part of fine filters. 

Hard water connection: 

  If the water contains impurities such as sand, iron particles or suspended particles, a 5 - 15 µm fine 

filter must be installed upstream from the hard water connection of the machine. 

  If the water is chlorinated Cl

2

 in excess of 0.1 mg/l (corresponding to 0.1 ppm), an activated carbon 

filter must be additionally installed upstream from the hard water connection on the machine. 

  Activated carbon filters may also be an integral part of fine filters. 

Special requirements: 

  If the chloride Cl

-

 concentration is in excess of 60 mg/l (corresponding to 60 ppm) and/or the 

concentration of silicate (SiO4) is ≥ 10 mg/l, there is a greater risk of corrosion. Thus the water for 

the entire water supply of the device must be treated with a reversed osmosis system. Make sure 

that the reference value of 10 µS/cm is maintained. 

  Reverse osmosis systems can be an alternative to full and/or partial demineralisation systems. 

Reverse osmosis systems remove almost all water-hardening substances and non-hardening 

minerals from the water. 

  If a combination of filters and water treatment system is installed, the following components must be 

installed in the specified order: sediment filter, hydrogen ion exchanger with activated carbon filter, 

shut-off valve. 

Regular maintenance on every type of water treatment unit is vitally necessary. 

Damages to Eloma machines resulting from neglect of maintenance will void warranty claims. 

Summary of Contents for Genius compact

Page 1: ...Eloma Combi Steamer Joker B Genius compact Joker T Joker B Genius compact Joker T Installation and Technical Connections...

Page 2: ...k for any transport damage Should there any signs of transport damage inform your dealer freight forwarder immediately For information and tips please contact Eloma GmbH Innovative Koch Backtechnik 82...

Page 3: ...quality 8 3 2 Connections 9 3 3 Diagrams for connection 9 3 4 Water connection for fresh water with water softener 9 3 5 Water connection for Osmosis Softened water and fresh water 9 3 6 Water connect...

Page 4: ...a potentially dangerous situation which if if not avoided will result in serious injury or death not avoided could result in serious injury not avoided could result in minor or moderate injury Caustic...

Page 5: ...or convection hot circulating air depending on the cooking mode selected with steam The device has three rotary knobs for input of time temperature and core temperature The cooking modes are entered w...

Page 6: ...the rack in place correctly Take care not to bend the tracks when doing this as this will stop grids trays and containers from being held securely in place Hand shower Water runs only when the oven i...

Page 7: ...onformity with NSF retrofit the device with the Foot Extension Kit 623 2 2 Recommended minimum clearance The machine may only be set up in a location with adequate lighting for users We recommend to i...

Page 8: ...water supply wash out clean the building pipe system All appliances are equipped as standard with 2 water connections for soft water and hard water Both connections are under the indication plate and...

Page 9: ...machine If the water is chlorinated Cl2 in excess of 0 1 mg l corresponding to 0 1 ppm an activated carbon filter must be additionally installed upstream from the soft water connection on the machine...

Page 10: ...ection for Osmosis Softened water and fresh water 3 6 Water connection for Osmosis Softened water 1 Drain 2 Tap raw water 3 Softened water 4 Power supply 5 Energy optimisation 6 Connection cleaner 7 C...

Page 11: ...agent The label on the oven indicates where the chemicals have to be connected Use the supplied clamps to connect the hoses to the oven Red for the cleaner and blue for the rinse agent Handling of cle...

Page 12: ...there is no on site siphon as a siphon is integrated in the device 1 Combi steamers 2 Fixed connection 3 Support stand Fixed connection with air exhaust pipe waste pipe with external siphon Applicatio...

Page 13: ...mers 2 Waste water pipe 3 Vent tundish 4 Siphon 5 Support stand Installing the waste water connection 1 Observe the local waste water regulations 2 Determine the connection version 3 Install the waste...

Page 14: ...230V AC 400 V 3N AC Fuse protection A 3x15 A 1x16 A 3x16 A The cross section of the power cables must be based on the current consumption and on local regulations For USA and Canada the applicable st...

Page 15: ...T Genius compact are identical Lrg Exhaust pipe A Drain 40 mm EWk Softened water G 3 4A TWk Tap raw water G 3 4A EZ Power supply EZEo Connection power optimisation PE Potential equalisation R Connecti...

Page 16: ...15 Englisch Art Nr ins_EL0510672_jb_jt_gc_08_enus...

Reviews: