3.6 Uninstalling the adapter drivers
Driver can be uninstalled in Device Manager, caption „Multiport serial
adapter” right click on device “Digi connect Wi-ME”, in menu select
“Uninstall”. After this procedure the devices “Digi connect ME” from
captions “Ports (COM & LPT)” and “Multiport serial adapter”
disappear.
3.7 Virtual Port settings
User can change settings in Device Manager. There should be
“Multiport serial adapter” caption, under the “Digi connect Wi-ME”
device. Select “Properties”, tab “Advanced”, button ”Properties”. Here
user can change a device name, COM port, IP address and port (assign
device with IP address to the COM port; you can list all devices in the
network by clicking “Browse”), enable ciphering.
Caption “Digi Connect Wi-ME (COMx)” allows to change proprietary
communication protocol (speed, parity and so on), but usually it is not
necessary as application overrides these settings.
3.8 Configuring the adapter over the web interface
The adapters network layer (Ethernet) can be configured either with web
browser or by an utility. It can be accessed by a Telnet too. Bellow
described is the web-interface. Notice, that entries may differ version by
version.
1.
Start configuration utility DigiConf. Here user can see the
configuration, change settings, start Telnet or web session and
restart the adapter. Double click the device or click “Open web
interface”
or put the interface's IP address straight to the address line of the
web-browser.
2.
Fill the name and password (default is: root/dbps).Then
configuration window appears (Pic. 4).