1.0 Introduction 

Ethernet as a communication medium becomes widely used not only in 

commercial  domain,  but  becomes  more  popular  in  industry  automation 
too. A RS485/422 interfaces are intended to connect multiple devices for 
distances  up to  1600m;  RS485  allows  half-duplex  communication,  while 
RS422  full-duplex.  An  adapter  E222  allows  to  integrate  the  RS485  or 
RS422 devices into the Ethernet network thereby bridge long distances. 

Bellow  described  adapter  allows  to  connect  RS485/RS422  devices 

together over the Ethernet network; it also allows to connect more devices 
to a single network gateway (i.e. computer). 

1.1 Application 

This communication device altogether with supplied software allows 

setting up following profiles: 

 

1)

 

Real Port profile. Adapter allows to connect a device with 
RS485/422 interface straight to computer via Ethernet protocol 
with virtual port application installed on, 

2)

 

Serial Bridge profile. Adapter connects two devices with 
RS485/422 interfaces like they were connected by cable; it is 
technique so called “serial tunneling” 

3)

 

TCP socket profile. Configured as TCP client or TCP server, 
establishes connection among these devices 

4)

 

UDP socket  profile. Configured as UDP client or UDP server, 
establishes connection among these devices. 

5)

 

Custom profile. Experienced user can access all settings both 
network and serial interfaces. 

 

2.0 How does it works? 

The  adapter  converts  RS485/422  signaling  to  the  Ethernet  interface.  In 

half-duplex  mode  selected,  it  can  drive  the  transmitting  direction 
automatically.  RS485/422  interface  is  presented  with  DB9M  (D-SUB, 
Canon,  male),  whereas  Ethernet  is  lead  out  via  standard  Ethernet  RJ-45 
socket. 

Summary of Contents for E222

Page 1: ...Communication adapter RS485 422 over the Ethernet ELO E222 User manual...

Page 2: ...2 connection 5 3 3 Power supply 6 3 4 Driver installation 6 3 5 Virtual COM port installation 7 3 6 Uninstalling the adapter drivers 9 3 7 Virtual Port settings 9 3 8 Adapter configuration over the we...

Page 3: ...profiles 1 Real Port profile Adapter allows to connect a device with RS485 422 interface straight to computer via Ethernet protocol with virtual port application installed on 2 Serial Bridge profile A...

Page 4: ...pter E222 installation process The process is divided to two sub processes software and hardware installation 3 1 Ethernet connection Adapter meets IEEE 802 3 specification and is to be plugged in to...

Page 5: ...he signal names is given in Tab 1 Signal Abbrev DB9M Direction Mode Transmitted Data Tx 2 OUT Transmitted Data Tx 7 OUT Received Data RxTx 3 IN Received Data RxTx 8 IN RS422 Data RxTx 3 OUT IN Data Rx...

Page 6: ...er supply The adapter can be powered with DC voltage source range 9 to 24V with DC connector outer inner diameter is 5 5 2 1 mm inner pin should have positive polarity The adapter can be powered via D...

Page 7: ...to install Virual Port application Bellow described process is for Windows XP for other Windows version the procedure is similar 1 Start the DigiWiz application on the dedicated computer which will gu...

Page 8: ...ollowing window Verify configuration eventually corrected by clicking Next To acknowledge click Next 8 On the screen Save settings is saved configuration and started installation of Serial adapter Dig...

Page 9: ...network by clicking Browse enable ciphering Caption Digi Connect Wi ME COMx allows to change proprietary communication protocol speed parity and so on but usually it is not necessary as application ov...

Page 10: ...nfirmed with Apply button 5 A Serial Ports section allows to set up device profile as described in chapter 3 9 User can choose among RealPort TCP UDP sockets Serial bridge and others 6 In a GPIO secti...

Page 11: ...the proper mode by clicking the port n link The Serial Port Configuration window appears Click the Change Profile link and choose the right profile Additional info can be found under the link More 1 R...

Page 12: ...erial device Flow Control set always to None and click Apply to save the configuration i In window Advanced Serial Settings check Enable RTS Toggle with default min values and click Apply j On Network...

Page 13: ...is effective for Microsoft Windows Open Device Manager expand Multiport serial adapter caption right click on the Digi connect ME device Select Proper ties tab Advanced button Properties The Advanced...

Page 14: ...ight be damaged In a while the green indicator ACT starts blinking indicating a network traffic Make sure drivers are installed see chap 3 5 Start DigiWiz application from supplied CD ROM and click Ne...

Page 15: ...network settings Everything works but serial connection Check a serial cable Check if the serial port installed in Device Manager Check adapter configuration especially serial interface Check proper t...

Page 16: ...28bit RS485 422 interface Connector DB9 male Transmission speed max 230 kb s Transmitted signals RS485 D Rx Tx D Rx Tx RS422 Tx Tx Rx Rx Flow control SW internal RTS signalling Others Configurability...

Page 17: ...ELO E222ZKE001 17...

Reviews: