Elo TouchSystems E222 User Manual Download Page 12

ELO E222ZKE001 

12 

 c)

 

On the Select Port Profile page, select Serial Bridge and click 
the “Apply” button.  

 d)

 

Check Initiate serial bridge to the following device.  

 

Enter the IP Address of the other device server.  

 

In the TCP Port box, type the Raw TCP port number for 
the destination serial port. If the serial port is the first or 
the only port on the device server, the value is 2101. 

 e)

 

Check  Allow  other  devices  to  initiate  serial  bridge.  The 
number of the TCP Ports must be same on both devices. 

 f)

 

Check  both  Enable  TCP  Keep-Alive  boxes  to  prevent  the 
freeze communication between devices. 

 g)

 

Click Apply to save the configuration. 

 h)

 

Configure  the  Basic  Serial  Settings  to  match  the  settings  of 
the  attached  serial  device.  Flow  Control  set  always  to  None 
and click Apply to save the configuration. 

 i)

 

In  window  Advanced  Serial  Settings  check  Enable  RTS 
Toggle 
with default min. values and click Apply

 j)

 

On  Network  Configuration  page  you  have  to  fill  fix  IP 
address,  Subnet  Mask  (default)  and  Gateway.  Gateway 
address box must be filled in with address of opposite device. 

 k)

 

Click Apply to save the new configuration. 

 l)

 

Follow the same steps to configure the other device server of 
the bridge, specifying the IP address of the first device server. 

 6.

 

Local Configuration and Modem Emulation - this mode is not 
applicable for this adapter (only RS232). 

 7.

 

Custom - the Custom Profile is an advanced option to allow full 
configuration of the serial port. 

 

 Keep in mind, once you configure the adapter to the Serial Bridge, you 

will be able to configure the adapter over the LAN  

No More!! 

If needed so, the factory reset must be done! 

Summary of Contents for E222

Page 1: ...Communication adapter RS485 422 over the Ethernet ELO E222 User manual...

Page 2: ...2 connection 5 3 3 Power supply 6 3 4 Driver installation 6 3 5 Virtual COM port installation 7 3 6 Uninstalling the adapter drivers 9 3 7 Virtual Port settings 9 3 8 Adapter configuration over the we...

Page 3: ...profiles 1 Real Port profile Adapter allows to connect a device with RS485 422 interface straight to computer via Ethernet protocol with virtual port application installed on 2 Serial Bridge profile A...

Page 4: ...pter E222 installation process The process is divided to two sub processes software and hardware installation 3 1 Ethernet connection Adapter meets IEEE 802 3 specification and is to be plugged in to...

Page 5: ...he signal names is given in Tab 1 Signal Abbrev DB9M Direction Mode Transmitted Data Tx 2 OUT Transmitted Data Tx 7 OUT Received Data RxTx 3 IN Received Data RxTx 8 IN RS422 Data RxTx 3 OUT IN Data Rx...

Page 6: ...er supply The adapter can be powered with DC voltage source range 9 to 24V with DC connector outer inner diameter is 5 5 2 1 mm inner pin should have positive polarity The adapter can be powered via D...

Page 7: ...to install Virual Port application Bellow described process is for Windows XP for other Windows version the procedure is similar 1 Start the DigiWiz application on the dedicated computer which will gu...

Page 8: ...ollowing window Verify configuration eventually corrected by clicking Next To acknowledge click Next 8 On the screen Save settings is saved configuration and started installation of Serial adapter Dig...

Page 9: ...network by clicking Browse enable ciphering Caption Digi Connect Wi ME COMx allows to change proprietary communication protocol speed parity and so on but usually it is not necessary as application ov...

Page 10: ...nfirmed with Apply button 5 A Serial Ports section allows to set up device profile as described in chapter 3 9 User can choose among RealPort TCP UDP sockets Serial bridge and others 6 In a GPIO secti...

Page 11: ...the proper mode by clicking the port n link The Serial Port Configuration window appears Click the Change Profile link and choose the right profile Additional info can be found under the link More 1 R...

Page 12: ...erial device Flow Control set always to None and click Apply to save the configuration i In window Advanced Serial Settings check Enable RTS Toggle with default min values and click Apply j On Network...

Page 13: ...is effective for Microsoft Windows Open Device Manager expand Multiport serial adapter caption right click on the Digi connect ME device Select Proper ties tab Advanced button Properties The Advanced...

Page 14: ...ight be damaged In a while the green indicator ACT starts blinking indicating a network traffic Make sure drivers are installed see chap 3 5 Start DigiWiz application from supplied CD ROM and click Ne...

Page 15: ...network settings Everything works but serial connection Check a serial cable Check if the serial port installed in Device Manager Check adapter configuration especially serial interface Check proper t...

Page 16: ...28bit RS485 422 interface Connector DB9 male Transmission speed max 230 kb s Transmitted signals RS485 D Rx Tx D Rx Tx RS422 Tx Tx Rx Rx Flow control SW internal RTS signalling Others Configurability...

Page 17: ...ELO E222ZKE001 17...

Reviews: