background image

ELOE174ZKE002 

 

5

4.0 

Specification 

 

4.1 

Parameters 

  Interface 

RS-422 

  RS-422 connector 

DB9F 

  Transmission mode 

full duplex 

 

4.2 

Optical parameters 

  Wavelength 

820mm, multimode fibre  

  Optic fibre 

2x 50/125 or 62.5/125 

  Connectors 

ST 

  Fibre optic cable 

two single mode fibres 9/125 

µ

  Maximum data rate 

115 200 bps 

 

4.3 

Other 

  Supply 

ext. DC supply of 6V/200mA galv. isolation 

 

DC supply of 8V/170 mA (from DTE) 

  Dimension: Length 

80mm 

 

Width 

55mm 

 

Height 

20mm 

  Weight 

80g 

  Stocking temperature 

-10° to +55°C 

  Working temperature 

+0° to +50°C 

  Humidity 

0 – 85% (non-condensing) 

 
 

5.0 

Testing 

When  the  power  supply  is  connected  the 
appropriate  LED  has  to  be  alight.  To  work 
properly at least one of 8V or 6V LED must be 
alight. 
The  LED  diodes  respective  to  the  optic 
transmitter/receiver 

(TRANSMIT/RECEIVE) 

must blink during transmission. 

 
 
 

Summary of Contents for E174

Page 1: ...RS 422 Multimode Fiber Optic Converter ELO E174 Operation manual ...

Page 2: ...peration principles 3 3 0 Installation 3 3 1 Optic link connection 3 3 2 RS 422 interface connection 3 3 3 Power supply connection 4 4 0 Specification 5 4 1 Parameters 5 4 2 Optical parameters 5 4 3 Other 5 5 0 Testing 5 6 0 Troubleshooting 6 7 0 Ordering Information 6 ...

Page 3: ...of the RS 422 interface Maximum data rate limit is 115 2 kbps LED diodes indicate the transmitted and received signal 3 0 Installation This part describes the ELO E174 converter installation principles 3 1 Optic link connection ST 400 connectors are used to connect the fiber optic cable To connect two converters the TRANSMIT connector of the local converter has to be connected to the RECEIVE conne...

Page 4: ...D labelled 8V indicates this supply The DTE receives the external supply information via OUT 5V signal This arrangement enables to back up the converter supply The external supply 6V is isolated from the RS 422 link Maximum take off is 170mA Caution Do not connect the DC connector if the supply is on Rx Rx Tx Tx GND Ready Vcc out stínění DB9 Signál female RS 422 1 RxA 2 RxB 3 TxA 4 TxB 5 NC 6 NC 7...

Page 5: ...00 bps 4 3 Other Supply ext DC supply of 6V 200mA galv isolation DC supply of 8V 170 mA from DTE Dimension Length 80mm Width 55mm Height 20mm Weight 80g Stocking temperature 10 to 55 C Working temperature 0 to 50 C Humidity 0 85 non condensing 5 0 Testing When the power supply is connected the appropriate LED has to be alight To work properly at least one of 8V or 6V LED must be alight The LED dio...

Page 6: ...allation are connected properly Check the power supply Connection in normal Check the power supply operation quit working Check if the cables are connected properly Check if the power supply is on Check if the DTE works properly 7 0 Ordering Information Supply code is ELO E174 Option Supply code for power supply 6V 200mA is ELO E0Q0 ...

Page 7: ...ELOE174ZKE002 7 Note ...

Page 8: ...ELOE174ZKE002 8 ...

Reviews: