background image

ELOE174ZKE002 

 

4

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

DTE 

 CABLE 

CONVERTER 

 
 
 

3.3 

Power supply connection 

To supply the converter, the external power supply of 6V via SCJ 2.5mm connector 
(yellow LED labelled 6V indicates it) or via 9 contact (IN+8V) is used, e.g. from 
the DTE. The green LED labelled 8V indicates this supply. The DTE receives the 
external supply information via OUT+5V signal. This arrangement enables to back 
up the converter supply. The external supply 6V is isolated from the RS-422 link. 
Maximum take off is 170mA. 
 
 

 

 

 

Caution! 

Do not connect the DC connector if the supply is on. 

 
 
 
 
 

Rx+ 

 

Rx-

 

Tx+

 

Tx-

 
 
 

GND

 

Ready

 

Vcc out

 

stínění 

DB9    Signál 
female   RS-422 

  RxA  

  RxB 

  TxA 

4  

  TxB  

5  

  NC  

6  

  NC  

7  

  GND signal 

 

 

8  

  OUT +5V  

  IN +8V  

kryt 

  stínění  

Summary of Contents for E174

Page 1: ...RS 422 Multimode Fiber Optic Converter ELO E174 Operation manual ...

Page 2: ...peration principles 3 3 0 Installation 3 3 1 Optic link connection 3 3 2 RS 422 interface connection 3 3 3 Power supply connection 4 4 0 Specification 5 4 1 Parameters 5 4 2 Optical parameters 5 4 3 Other 5 5 0 Testing 5 6 0 Troubleshooting 6 7 0 Ordering Information 6 ...

Page 3: ...of the RS 422 interface Maximum data rate limit is 115 2 kbps LED diodes indicate the transmitted and received signal 3 0 Installation This part describes the ELO E174 converter installation principles 3 1 Optic link connection ST 400 connectors are used to connect the fiber optic cable To connect two converters the TRANSMIT connector of the local converter has to be connected to the RECEIVE conne...

Page 4: ...D labelled 8V indicates this supply The DTE receives the external supply information via OUT 5V signal This arrangement enables to back up the converter supply The external supply 6V is isolated from the RS 422 link Maximum take off is 170mA Caution Do not connect the DC connector if the supply is on Rx Rx Tx Tx GND Ready Vcc out stínění DB9 Signál female RS 422 1 RxA 2 RxB 3 TxA 4 TxB 5 NC 6 NC 7...

Page 5: ...00 bps 4 3 Other Supply ext DC supply of 6V 200mA galv isolation DC supply of 8V 170 mA from DTE Dimension Length 80mm Width 55mm Height 20mm Weight 80g Stocking temperature 10 to 55 C Working temperature 0 to 50 C Humidity 0 85 non condensing 5 0 Testing When the power supply is connected the appropriate LED has to be alight To work properly at least one of 8V or 6V LED must be alight The LED dio...

Page 6: ...allation are connected properly Check the power supply Connection in normal Check the power supply operation quit working Check if the cables are connected properly Check if the power supply is on Check if the DTE works properly 7 0 Ordering Information Supply code is ELO E174 Option Supply code for power supply 6V 200mA is ELO E0Q0 ...

Page 7: ...ELOE174ZKE002 7 Note ...

Page 8: ...ELOE174ZKE002 8 ...