ELOE171ZKE001

 

        

 

 

 

3.2 

Fibre Link Connection 

The  fibre  optic  cable  is  connected  through  the  ST400  connectors.  To  connect  the 

ELO E171, the transmitter of the remote converter must be connected to the receiver of 

the local ELO E171 and the remote receiver must be connected to the local transmitter 

(fibres cross). 

Both converters must be set to the right data range and data format. The rotating switch 

on the top converter case is used to it. 

 

3.3 

Power Connection 

The  external  supply  has  to  have  the  output  voltage  of  12-24V  and  it  is  connected  via 

DC+ and DC- clamps. The supply take off is c.200 mA. If the supply is on operation the 

indicator RUN switches on.  

The converter contains two isolated zones. The RS-485 circuits are separated from the 

other ones and supplied via the internal isolated DC/DC converter. If it is necessary to 

keep this separation the external power supply must be isolated from the signal grounds 

of all RS-485 partners. 

 

4.0 

Specification 

4.1 

Parameters 

  Transmitted signals 

differential signal AB 

  Type and connection of RS-485 connector 

clamps 

  Isolation 

RS-485 galvanic isolation from GND 

 

3 kV/1 sec supply 

  Transmit mode 

asynchronous, half-duplex 

  Fibre optic cable 

two multimode fibres  

 

cables 50/125 

µ

m (62/125

µ

m)  

  Optic connectors 

ST type 

  Maximum data rate 

115 200 bps 

  Minimum data rate 

1200 bps 

  Supply 

external DC supply 9-24V/200 mA 

  Dimension: 

Length 

115 mm 

 

Width 

55 mm 

 

Height 

24 mm 

  Weight 

137 g 

Summary of Contents for E171

Page 1: ...RS 485 to Multimode Fibre Optic Converter ELO E171 Operation manual ...

Page 2: ...onverter 3 2 0 Operation principles 3 3 0 Installation 3 3 1 RS 485 Interface Connection 4 3 2 Fibre Link Connection 5 3 3 Power Connection 5 4 0 Specification 5 4 1 Parameters 5 4 2 Other 6 5 0 Testing 6 6 0 Troubleshooting 6 7 0 Ordering Information 6 ...

Page 3: ...s the signal transfer the converter matches the full duplex fiber to the half duplex RS 485 data flow direction switching Its independent operation is based on the set data rate 1200 to 115200 bps and data format which must be asynchronous of 10 and or 11bits start bit 8 to 9 information bits stop bit The switching speed is sufficient to use the converter in data transmission network organized as ...

Page 4: ...d they influence the transfer immunity against interference Inserting the optical converter into the metallic link terminates this link right on the A B clamps of the converter therefore it is necessary to connect the passive converter There are also the active terminators beside the passive ones Only one active terminator can be installed to one metallic section of the link and its role is as fol...

Page 5: ... is on operation the indicator RUN switches on The converter contains two isolated zones The RS 485 circuits are separated from the other ones and supplied via the internal isolated DC DC converter If it is necessary to keep this separation the external power supply must be isolated from the signal grounds of all RS 485 partners 4 0 Specification 4 1 Parameters Transmitted signals differential sig...

Page 6: ...be alight The TxD and RxD indicators must blink during transmission 6 0 Troubleshooting Symptom Action ELO 171 does not work Check if the RUN is alight after installation Check the power supply Check the RS 485 link connection Connection in normal Check the power supply operation quit working Check if the cables are OK Turn off and on the power supply and detect if the converter starts again 7 0 O...

Page 7: ...ELOE171ZKE001 7 Note ...

Page 8: ...ELOE171ZKE001 8 ...

Reviews: