![Elmo Gold Solo Double Twitter Series Installation Manual Download Page 56](http://html.mh-extra.com/html/elmo/gold-solo-double-twitter-series/gold-solo-double-twitter-series_installation-manual_2394495056.webp)
Gold Solo Double Twitter Installation Guide
MAN-G-SOLTWIB_160 (Ver. 1.005)
|
J11 I/O and Communication Connector|
www.elmomc.com
56
Table of Contents
8.4.2.
Digital Outputs
8.4.2.1.
Source PLC Voltage Level Digital Output
Feature
Details
Type of output
Optically isolated PLC source
Supply output (VDD)
12 V to 30 V (typically 24 V)
Max. output current
I
out
(max) (V
out
= High)
I
out
(max) ≤ 30 mA
Collector Emitter saturation voltage
1 V
T
on
(Time from low to high)
If V
dd
= 24V
< 15
µ
sec
T
off
(Time from high to Low)
< 250
µ
sec
R
L
The external R
L
must be selected to limit output
current to no more than 30 mA.
𝑅𝑅
𝐿𝐿
=
𝑉𝑉𝑉𝑉𝑉𝑉−1
𝐼𝐼
𝑜𝑜𝑜𝑜𝑜𝑜
(
max
)
Executable time
0 < T < 250
µ
sec
Figure 33: Digital Photodarlington Output Schematic – Source Mode PLC Level