Gold Solo Double Twitter Installation Guide
MAN-G-SOLTWIB_160 (Ver. 1.005)
|Control Supply Input Voltage (VL)|
www.elmomc.com
11
Table of Contents
4.3.
Control Supply Input Voltage (VL)
The Control Supply input voltage (VL) must be either SELV or PELV rated.
Feature
Unit
Details
Standard CAN (S option)
Input range
V
11 V – 95 V
Power consumption
(including 5 V/200 mA for encoder)
W
< 2.5 W
ETHERCAT (E option)
Input range
V
11 V – 95 V
Power consumption
(including 5 V/200 mA for encoder)
W
< 4 W
4.4.
Product Features
Main Feature
Details
Presence / No.
STO
+5V Logic, Opto isolated from the Control section,
or
√
PLC Source, Opto isolated from the Control section
√
Digital Input
+5V Logic, Opto isolated from the Control section
or
6
PLC Source, Opto isolated from the Control section
or
6
PLC Sink Opto isolated from the Control section
6
Digital Output
+5V Logic, Opto isolated from the Control section
or
4
PLC Source, Opto isolated from the Control section
or
4
PLC Sink, Opto isolated from the Control section
4
Analog Input
Differential ±10V or Single Ended
1
Feedback
Standard Port A, B, and C
√
Communication
Option
USB (only for EtherCAT version)
√
EtherCAT
or
√
CAN
√
Standard RS232
√