STX2402-E 

STX2402-C

 

 

The STX2402-x is an EN54-4 approved power supply ideal for use in Fire and Smoke and ventilation 

control Systems. Its regulated 27.6V dc output will supply up to 2.0 Amps continuous into the load, in 

addition to providing up to 700 mA for charging the standby batteries up to 17 Ah. The power supply 

output features electronic short circuit protection under both mains and standby battery operation. 

Maximum battery life is assured through continuous active battery monitoring and the use of a two 

stage charger, comprising bulk and temperature compensated final float phase depending upon 

battery condition. Once fully charged the product operates in Eco power saving mode, whereby it will 

check and top up battery charge every 24 hours, but will not waste energy by continuously attempting 

to charge a fully charged battery. This also extends the operating life of the batteries. Deep discharge 

protection prevents premature battery failure when operating from standby for extended periods. 

Two sets of volt free solid state relay fault output signal (i) loss of mains and (ii) battery fault, charger 

fault and loss of output. In addition there is an optional plug in serial interface that can provide 

diagnostic and fault reporting information to supervisory systems. 

 

 

Certified by UL to EN54-4:1997 +A1: 2002 + A2: 2006.

 

 

Up to 2.0A current to load at 27.6V dc nominal regulated output.

 

 

Charging capability to support 7 or 17Ah batteries.

 

 

Electronic overload protection shuts down output until overload or short circuit is removed.

 

 

Battery Monitor detects battery missing, low battery, short-circuit or reverse connection.

 

 

Battery charging circuit is energised only when a battery is correctly connected and the battery voltage 

is greater than 14 V.

 

 

No loss of output during automatic connection of battery to load on loss of mains.

 

 

Deep discharge protection disconnects battery from load when battery voltage falls below 21 V.

 

 

Diagnostic indicator LED (Orange) (Internal).

 

 

Fault indicator LED (Yellow) flashes on detection of output fault, battery fault, charger fault and mains 

failure.

 

 

Mains indicator LED (Green) showing mains present Indicators check at start-up.

 

 

Optional RS232 serial interface for fault reporting and diagnostics.

 

F

EATURES

 

www.acornfiresecurity.com

www.acornfiresecurity.com

Summary of Contents for STX2402 Series

Page 1: ...relay fault output signal i loss of mains and ii battery fault charger fault and loss of output In addition there is an optional plug in serial interface that can provide diagnostic and fault reportin...

Page 2: ...I 2 x 17 Ah 12 V PS12170 NP17 12I Battery Charging Constant current bulk charging to 80 capacity within 24 hours Float charging to 100 within 48 hours Eco charging and check every 24 hours for up to 8...

Page 3: ...tion Mains present Battery healthy None OPEN CLOSED Standby Mode Mains lost Battery driving load Investigate loss of mains CLOSED OPEN Fault Present Blown fuses Battery fault Internal fault Investigat...

Page 4: ...lled no further than 10cm from the CIE and close coupled byconduit This unit must be fed from a mains power source having a separate approved disconnect device and fitted with a fuse or other over cur...

Page 5: ...eing used to power the CIEdirectly 8 Fix to wall or other structure in correct orientation i e with hinge on left hand side using screws of sufficient size and length through the mounting holes 9 Prot...

Page 6: ...hole Figure 3 Connections Battery Select Mains ON Diagnostic LED Fault LED L E N Mains Temperature Sensor connect To Load 6 Re apply mains Verify that the green Mains LED illuminates and the yellow Fa...

Page 7: ...t the green Mains LED illuminates and the yellow Fault LED extinguishes 18 If connected verify that the EPS Fault monitor shows a closed contact and the GEN PSU Fault monitor shows a closed contact 19...

Page 8: ...batteries must be removed and disposed separately via an appropriate approved battery disposal route in accordance with all national and local regulations Package used batteries safely for onward tra...

Reviews: